Page 1
19 494 English ..1 Français ..2 Español ..3 Essence Design + Engineering GROHE Germany 96.615.031/ÄM 225453/01.13...
Page 2
Please pass these instructions on to the end user of the fitting! S.v.p remettre cette instruction à l'utilisateur de la robinetterie! Entregue estas instrucciones al usario final de la grifería!
Page 5
English Installation 8. Grease seal (K) with the grease provided, slide the escutcheon mounting base (L) on and tighten with 1. Remove the two screws (A1) from the fitting template (A), screws (L1). then remove the template, see Fig. [1]. Do not use excessive force to tighten the screws.
Page 7
English Maximum hot water limit setting 5. Align the white mark (D1) on the limit stop against the number (1 to 10, see Fig. [6]) you have selected on the dial The adjustable hot water limit stop (D) is factory set in a and slide the limit stop (D), see Fig.
Page 9
English Maintenance 9. Pull the pressure balancing cartridge (V) out of the valve Check, clean and if necessary, replace parts. Grease with body noting the location of "H" and "C", see Fig. [13]. special valve grease. 10. Remove the check valve inserts (W), see Fig. [14]. If the check valves are removed it is important to reinstall them I.
Page 12
Grohe America Inc. Grohe Canada Inc. 241 Covington Drive 1230 Lakeshore Road East Bloomingdale, IL Mississauga, Ontario 60108 Canada, L5E 1E9 U.S.A. Technical Services Technical Services Services Techniques Phone: 630/582-7711 Phone/Tél: 905/271-2929 Fax: 630/582-7722 Fax/Télécopieur: 905/271-9494...