17. Tool inications and warning signals
17.1
Indication of charger
17.2
Warning tone of the battery
Warning note
Interval
0.3
1 time
second
0.3
2 times
second
0.3
3 times
second
0.3
4 times
second
0.1
4 short note
second
0.3
10 times
second
1 long note
5 second
38
Li-Battery
LED
Battery capacity
Three squares green
Two squares green
One squares green
One squares red
Charger
Indication
Red
Green
Warning
Situation or Problem
Frequency
Indicate: start up and shutdown, small and big blade
No repeat
mouth switch
Indicate: is charging or shear is not connected well,
10 repeats
please check if the nuts at both ends of the shear and
battery is connected firmly.
Indicate: open hall signal of stroke plate faults
10 repeats
Send the shear to Customer Assistance
Indicate: closed hall signal of stroke plate faults
10 repeats
Send the shear to Customer Assistance
The battery is used up. Please charge the battery
No repeat
soon.
The scissor has worked for 100,000 times already.
10 repeats
Please remove the front cover, blade, pin, lead screw
and re-grease the connection joints.
Scissor has worked for 500,000 times, and it should be
10 repeats
inspected and maintained fully. Please contact your
local dealer for servicing.
Voltage
80%-100%
50%-80%
34 V <Vcc≤42 V
30%-50%
Below 30%
Vcc≤34 V
Situation
Charging
Charging finished

Publicité