Storage After Use; Maintenance; Troubleshooting - Jetboil MIGHTYMO Instructions

Table des Matières

Publicité

Packing:
1. Allow stove to fully cool before packing. 2. Remove stabilizer
from canister and fold for storage (2.1). 3. Fold valve bail under
valve body (2.2). 4. Fold pot support legs into closed position (2.3)

STORAGE AFTER USE

1. Always disconnect fuel canister before storing the stove. 2. Ensure
stove is clean and dry before storing. 3. Store the stove in a cool,
dry location, indoors.

MAINTENANCE

1. Flame Check (Every use): The height of the flame should
increase from low to high with counter-clockwise rotation of the
control valve. Flame should be blue with no yellow tipping at
full output. Flame should not flash back into burner or lift off of
burner top. If flame abnormalities are found, see your dealer or
contact Jetboil for service.

TROUBLESHOOTING

1. Flame does not extinguish: Tighten valve as much as possible,
blow out flame, and immediately detach fuel source. See your
dealer or contact Jetboil for service.
2. Igniter fails to spark: If igniter will not spark, check positioning
of electrode in relation to burner. Approximately 1/8" (3mm)
length of igniter wire should protrude from the igniter ceramic.
Wire should point toward center of burner with a 1/8" (3mm) gap
between the end of the wire and the top surface of the burner. If
not positioned as described, re-position the electrode accordingly
or pull igniter wire through ceramic and cut wire ¼" above top of
ceramic. Bend wire towards center of burner head and position as
described above. If stove is wet, igniter may fail to spark. If igniter
fails to spark, use matches or a lighter, following instructions
detailed in OPERATING INSTRUCTIONS – Lighting the Burners.
See your dealer or contact Jetboil for service if igniter fails to
spark for any other reason.
9
3. If an issue cannot be corrected using these instructions, see
Limited Warranty on back page.
10