B. Invert cap in appliance pressure regulator
With the appliance installed, identify the type of
appliance regulator on the unit and follow the
instructions in the appropriate illustration.
CONVERSION OF MAXITROL APPLIANCE
PRESSURE REGULATOR
FIGURE 13
CONVERSION OF HARPER-WYMAN APPLIANCE
PRESSURE REGULATOR
FIGURE 14
C. Low Flame Adjustment
This appliance is shipped from the factory with low
and medium flame settings adjusted for use with
natural gas. If further adjustment is necessary, or to
readjust for use with LP, proceed as follows:
1. Light burner and set control knob for low flame.
2. Remove control knob from valve stem.
CAUTION: NEVER USE A METAL BLADE TO PRY
KNOB OFF. IF KNOB CANNOT BE EASILY
REMOVED, TUCK THE FOLDS OF A CLOTH
DISHTOWEL UNDER THE KNOB AND PULL THE
TOWEL OUTWARD WITH STEADY, EVEN
PRESSURE.
3. Insert a slender, thin-blade screwdriver into the
recess at center of valve stem and engage blade
with slot in adjusting screw.
4. Turn center stem adjusting screw to set flame size.
. . . clockwise to reduce
. . . counterclockwise to increase
5. Replace control knob when adjustment is
completed.
Proper adjustment will produce a stable, steady blue
flame of minimum size. The final adjustment should be
checked by turning knob from high to low several times
without extinguishing the flame.
This adjustment, at low setting, will automatically provide
the proper flame size at medium setting.
After Conversion Steps A, B and C have been completed,
check the appearance of each burner's flame at the Hi
and Lo settings against figure 16. If the flames appear too
large or too small, review each step to make sure it was
completed correctly.
FLAME APPEARANCE AT HI, MED & LOW
8
FIGURE 15
FIGURE 16