INSTALLATION
ATTENTION
Bear in mind the position of the maximum consumption Switch.
If you do not use cable suitable for the distance and power of the Kit, it will not work
properly and may cause overheating in the electrical circuits with the risk of an electrical
accident. Always use the cable with a section suitable to maximum consumption. In the
event of doubt between two values, always use the cable with greater section.
To connect the power supply of the Kit, locate the free packing gland at one end of the Automatic
- Manual Selector panel.
Make sure that there is no electrical current in the connection cable (differential switch in the OFF
position).
Take the cable to the panel of the Kit.
Single line (1 x 16 A) LowAmp or (1 x 32 A) HighAmp:
Open the cabinet of the Automatic - Manual Selector, insert the cable through the free packing
gland and connect the Neutral marked with N, the line or phase to the terminal marked L and the
earth in the special, green and yellow, earth terminal.
12