INSTALLATION
HIGH AMP FOR BP SYSTEMS
With this configuration, all the elements of the kit can operate at the same time. This configuration
uses a greater amount of electricity.
LOW AMP / HIGH AMP configurations can be changed using the switches on the electric
panel. The configuration options of the electric panel are shown further on in this Manual.
For High Amp you should put A2-A3-A4 in On position and A5 in Off position like the picture
below.
SWITCHBANK S1 OFF
TEST MODE OFF
DON'T ADD 1 HS PUMP W/HTR
DON'T ADD 2 HS PUMPS W/HTR
230V 1ϸ
DON'T ADD 4 HS PUMPS W/HTR
1x32A
SPECIAL AMPERAGE RULE A
STORE SETTINGS*
1 MIN HTR COOLDOWN (ELEC)
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
* SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION
IMPORTANT NOTE:
You can consult both the "Low Amp" and the "High Amp" power in the Electrical Specifications
attached to this manual.
To determine the section of the electrical installation leads, see the values given in the
aforementioned Electrical Specifications together with the following table:
List of sections, distance and power required
2,1
Distance
6 - 11 m
2,5
11 - 15 m
2,5
15 - 20 m
4
For greater distances, increase the cable section proportionally.
There may be configurations which require the installation of 1 line of 16 A, 1 line of 32 A to cover
the power required by the Spa.
The configuration options of the electrical panel are given further on in this Manual.
Please remember that the installation and electrical configuration changes can only be performed
by qualified people and always following the current regulations in each country.
The manufacturer is not liable, under any circumstances, for damage caused by incorrect
installation or performed by non-qualified people.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
2,5
2,8
3,2
3,5
Nominal section of the cable in mm
2,5
2,5
2,5
4
2,5
4
4
4
4
4
6
6
SWITCHBANK S1 ON
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B
MEMORY RESET*
5 MIN HTR COOLDOWN (GAS)
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
KW required
4,4
5,3
6,2
4
6
10
6
6
10
6
10
10
ENG
7,0
7,9
8,8
2
10
10
10
10
10
10
10
16
16
11