Selecting factory parameter sets (presets)
1. In order to activate the EDIT mode, press the EDIT key.
Only with active security locking - [lock] flashes:
2. Press the UP/DOWN key until the desired security code is set and confirm by pressing the EDIT
key.
[Out] flashes.
3. Press the UP/DOWN key until [Set1 Set2 Set3] flashes in the display, then press the EDIT key.
[Set1], [Set2] or [Set3] flashes.
4. Select the desired factory parameter record value with the UP/DOWN keys.
Set1 (parameter set 1): fast control response
Set2 (parameter set 2): universal control response
Set3 (parameter set 3): precise control response
Selected parameter set flashes. To confirm, press the Edit key.
The VPPM-...C1 is in the RUN mode again.
Fig. 27
Setting the unit and security code
1. In order to activate the EDIT mode, press the EDIT key.
Only with active security locking - [lock] flashes:
2. Press the UP/DOWN key until the desired security code is set and confirm by pressing the EDIT
key.
[Out] flashes.
3. Press the UP/DOWN key until [SPEC] flashes in the display, then press the EDIT key.
The current unit [kPA] or [psi] or [bar] flashes.
4. Select the desired unit [kPA], [psi] or [bar] with the UP/DOWN buttons. The selected unit
flashes. To confirm, press the EDIT key.
[Lock] flashes, display [OFF] or display of security code.
5. Set the desired security code, maximum 4-figure, with the UP or DOWN key (OFF = no protec­
tion). To confirm, press the EDIT key.
Tip:
Keep the security code where it can be found.
If the security code is forgotten è Section 7.
6. To confirm, press the EDIT key.
The VPPM-...C1 is in the RUN mode again.
Fig. 28
• Connect the VPPM-...C1 with a setpoint value signal. The VPPM-...C1 possesses
a so-called "differential input". The setpoint value signal 0 ... 10 V is then ap­
plied to contacts 3 and 4, whereby the lower potential must be connected to
contact 3 and the higher potential to contact 4. Contact 3 (– setpoint value) can
be connected to contact 7 (0 V DC).
• Supply the VPPM-...C1 with direct current (supply voltage UV = 24 V DC ±10 %).
• Pressurize the VPPM-...C1 with a supply pressure at least 1 bar higher than the
maximum desired outlet pressure. An outlet pressure p2 proportionate to it is
then set. The following outlet pressure is then assigned to the setpoint value
signal:
VPPM-...C1 Outlet pressure with
1)
signal 1 % FS
2 bar type
0.02 bar
6 bar type
0.06 bar
10 bar type
0.1 bar
1) –
FS = Full scale: 1 % FS = 0.1 V or 4.16 mA/100 % FS = 10 V or 20 mA
Outlet pressure: 0 V or 4 mA generates an outlet pressure of 0 bar
Fig. 29
Select a suitable parameter set:
Recommended parameter sets VPPM-... size 1/8"
1)
Tube length
Open
system
0 m
3
1 m
3
3 m
3
³ 5 m
3
1) With tubing inner diameter 6 mm for 1/8" or 8 mm for 1/4"
Fig. 30
Outlet pressure with
1)
signal 100 % FS
2 bar
6 bar
10 bar
Output volumes in ml
0 ... 100
100 ... 1000
3
2
3
2
3
3
3
3
Recommended parameter sets VPPM-... size 1/4"
Tube length
0 m
1 m
3 m
³5 m
With tubing diameter 8 mm or 10 mm
1)
Fig. 31
Recommended parameter sets VPPM-... size 1/2"
Tube length
0 m
1 m
3 m
³ 5 m
1) With tubing diameter 12 mm or 16 mm
Fig. 32
7
Operation
Note
When switching off the VPPM-..., make sure that first the setpoint value is set to
0 V or 4 mA, then the supply pressure, after that the setpoint value, and finally
the supply voltage is switched off.
Reset VPPM-...C1 to factory setting
(also if the security code cannot be found)
Note
By resetting to factory settings, the current settings are lost.
• Carry out the following steps:
Resetting the VPPM-...C1
1. Press and hold down the UP, DOWN and EDIT keys.
2. Switch on the operating voltage.
3. Release the keys again.
[ALL] flashes.
4. With the UP or DOWN keys, select which parameters are to be reset to the factory setting:
[Out] flashes:
[In] flashes:
[All] flashes:
5. Press the EDIT key to reset the selected parameters
The VPPM-...C1 is in the RUN mode again.
Fig. 33
8
Maintenance and care
> 1000
Cleaning:
1
• Switch off the following energy sources to clean the outside:
2
Operating voltage
2
– compressed air
2
• If necessary, clean the VPPM-...C1 on the outside with a soft cloth.
Permitted cleaning agents are mild soapy water (max. +50 °C) or all non-abrasive
media.
1)
Open sys­
Output volumes in ml
tem
0 ... 500
3
1
3
1
3
2
3
3
1)
Open
Output volumes in ml
system
0 ... 2000
3
1
3
1
3
2
3
3
reset all output parameters
reset all input parameters
reset all output and input parameters as well as the
security code
500 ... 2000
> 2000
2
3
2
3
3
3
3
3
2000 ... 10000 > 10000
2
3
2
3
3
3
3
3