FOR SERVICE TECHNICIAN'S USE ONLY
Service Code
Failure Description
Shown on Display
F-56
Wrong or invalid configuration
F-58
Wrong or invalid configuration
F-60
UI does not work
F-61
Power control board does not
work
C-81, C-82
Over temperature
To check for proper voltage, complete the following steps:
1.
Disconnect power.
2.
Connect voltage measurement equipment.
Location on the cooktop
EMI filter board
Power control board (PC)
Left and right
Power control board (PC) to blower fan
Left and right
Power control board (PC) to the element
sensor
Left and right
Power control board (PC) to the User
Interface
Type of Failure
Type 3
Type 2
Type 3
Type 2
Type 2
Component Testing Chart
Checkpoints
J1 - (L) (N)
J1 - (L) (N)
J205 - (00) - (22)
J205 - (00) - (60)
J604 - (1) - (2)
J605 - (1) - (2)
J806 - 00
J806 - 88
J806 - 99
J806 - 22
J806 - 44
(Each of these pins refers to J806 - 99
[0VDC, Neutral pin])
4
Repair Suggestions
1.
Disconnect power.
2.
Reconnect power.
3.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
4.
If the issue is not fixed, disconnect power.
5.
Replace the User Interface.
6.
Replace all parts and panels before operating.
7.
Reconnect power.
8.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
1.
Disconnect power.
2.
Reconnect power.
3.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
4.
If the issue is not fixed, disconnect power.
5.
Replace the power control board.
6.
Replace all parts and panels before operating.
7.
Reconnect power.
8.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
1.
Disconnect power.
2.
Replace the User Interface.
3.
Replace all parts and panels before operating.
4.
Reconnect the power.
5.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
1.
Disconnect power.
2.
Check that the cables between the User Interface and the power
control board are not damaged and are firmly plugged in.
3.
Check for 240 volts AC at the J1 connector on the power control
board by completing the following steps.
4.
Connect voltage measurement equipment.
5.
Reconnect power and confirm voltage reading. If voltage is not
correct, disconnect power and have a qualified electrician check
the home power supply.
6.
If voltage is correct, disconnect power and replace the cable
between the User Interface and the power control board.
7.
Replace all parts and panels before operating.
8.
Reconnect power.
9.
Reconfigure the cooktop following the directions in "Manual
Configuration Mode."
Not enough ventilation: Check the cooktop installation according to
the Installation Instructions. In particular, check the blower intakes.
3.
Reconnect power and confirm voltage reading.
4.
Disconnect power after performing voltage measurements.
Results Voltage
From 208VAC to 240 VAC -60Hz
From 208VAC to 240 VAC -60Hz
From 0VDC to 12VDC
+5VDC
0V
+10.5V
0VDC
From 0VDC to 12VDC