over the manual and the unit cannot
then be switched off using a switch.
Settings:
The fans are set to operate at 60%
relative humidity and with 2 minutes
run-on time.
If the humidity in the room is lower than
60%, the fan will not turn on. If it is higher,
the fan will operate until the humidity level
drops below 60%RH and then runs for
the length of time set by the timer. The
desired humidity level and time delay are
set by means of adjusters positioned on
the printed circuit board (fig. 9) and
accessible once the grille (1) has been
removed.
The humidity is set by the adjuster. "% Hr"
- To reduce the humidity setting turn
anticlockwise (min.60 %)
- To increase the humidity setting turn
clockwise (max. 90 %)
The timer is set by the adjuster "t min."
- To reduce the run-on time, turn
anticlockwise (min. 2 minutes)
- To increase the run-on time, turn
clockwise (max: 20 minutes).
ATTENTION: When the fan is on
run-on time phase, you must let it
finish before a new setting.
Note:
If the fan never turns on.
- Humidity adjuster is not at its lowest
setting. Turn anticlockwise the adjuster
(do not force the adjuster) to the
minimum setting.
- The fan is fitted in an area where there
is no air flow.
- The humidity level in the room is below
60% RH
If the fan never stops:
- Humidity adjuster is not at its highest
setting. Turn clockwise the adjuster (do
not force the adjuster) to the maximum
setting.
- The humidity level in the room is above
90% RH
DECOR-100 CD and CDZ
Models provided with a PIR (passive
infra-red) detector and adjustable "run
on" timer (1 to 30 minutes).
The unit starts automatically when a
movement is detected with a maximum
distance of 2 metres (fig.8) and will
continue to operate for the set period.
The desired run-on time is selected by
means of an adjuster positioned on the
printed
circuit
accessible once the grille (1) has been
removed:
- To reduce the run -on time, turn
anticlockwise (min. 1 minute)
- To increase the run -on time, turn
clockwise (max: 30 minutes).
Maintenance
The extractor fan only requires periodical
cleaning using a cloth lightly impregnated
with a soft detergent.
After Sales Service
We recommend you not to try to
dismantle or remove any other parts than
those mentioned as any tampering would
automatically cancel the S&P guarantee.
If you detect any fault, contact your S&P
dealer.