6.2.4 Protective Conductor Connection
In general, consider the following when connecting a protective conductor:
 Always connect the protective conductor.
 Use cable lugs for external protective conductor connection.
 Permanently install the protective conductor close to the enclosure.
 Connect all uncoated, non-energised metal parts to the protective conductor system.
 Neutral conductors have to be installed as live conductors.

6.2.5 Installation Conditions

During installation – wiring inside the terminal box – sufficient distance must be
maintained between the electrical lines themselves and between electrical lines and
components. This then provides sufficient insulation against voltage punctures in the
interior.
Installation conditions for creepage distances and clearances
212727 / 815060300170
2021-02-25·IO00·III·en·02
X I *
I =
Minimum distance to enclosure
according to ANSI/ISA/UL 60079-7;
CSA C22.2 no. 60079-7 standards
y =
Clearance
X =
Factor in accordance with ANSI/
ISA/UL 60079-7; CSA C 22.2 no.
18591E00
60079-7 depending on conductor
cross-section
X * I = Minimum distance
18590E00
18592E00
m =
50 mm/1.97 inch distance between
Ex e and Ex i terminal blocks
c =
8 mm/0.31 inch distance between
Ex e and Ex i cable lines
18593E00
Terminal boxes
Series 8150/1, Series 8150/2
Mounting and Installation