6
Mounting and Installation
Mount the device carefully and only in accordance with the safety notes
(see "Safety" chapter).
Read through the following assembly instructions carefully and follow them precisely.
6.1
Mounting / Dismounting, Operating Position
6.1.1 Operating Position
DANGER! Risk of explosion if device installed in incorrect position!
Non-compliance may result in fatal or serious injuries.
The device must be secured to the floor or a wall only – it is not designed to be
installed overhead or used as a free-standing unit.
Install the device on a level surface only.
Align the enclosure depending on the mounting type:
• For vertical installation: Any orientation.
• For horizontal installation: Cover on top.
• The device must not be suspended above the ground/the cover must not be at an angle.
6.1.2 Mounting the Enclosure
Secure the device using the anchoring brackets. Secure the device using the anchoring
brackets.
All dimensions in mm [inches]
7 [0,28]
ø
7
[ø 0,28]
X
18 [0,71]
26 [1,02]
212727 / 815060300170
2021-02-25·IO00·III·en·02
14282E00
x
Mounting and Installation
≦ 90°
Variant
Standard
8150/.-....-....-...-4...
8150/-....-....-...-5...
8150/.-....-....-...-6...
8150/.-....-....-...-....-AR
8150/.-....-....-...-....-CC
20946E00
Terminal boxes
Series 8150/1, Series 8150/2
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
16523E00
US
US
US
US
Dimen-
sion X
10 [0.39]
20 [0.79]
15 [0.59]
25