Appendix
Technical data
Input voltage
Input power
Nominal current
Max. output power
Max. nominal current
Air flow rate
Refrigerant
Fill level
Intake pressure
Discharge pressure
Dehumidification
performance/24 h*
Recommended room size
Operating temperature
Dimensions
Weight
* The lower the ambient temperature and the colder the temperature outside
becomes, the less moisture accumulates in the air and flows from outside into
the room to be dehumidified. For this reason, dehumidification performance
steadily decreases when temperatures drop and can come to a standstill. This
does not mean that the appliance is defective.
SLE 200 A1
220–240 V ∼ (alternating current), 50 Hz
200 W
1.25 A
245 W
1.4 A
120 m³/h
R290
35 g
1.2 MPa
2.5 MPa
10 l (at 30°C/80% rh)
5 l (at 27°C/60% rh)
approx. 16 m
2
or approx. 37 m
(at a ceiling height of 2.3 m)
5°C to +32°C
approx. 28 x 46 x 24 cm
approx. 8.5 kg
3
GB │ IE
│
17
■