Audible Continuity Test - VOLTCRAFT VC-5081 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

e) Audible continuity test
Make sure that the circuit components, circuits and components to be measured or any other
measuring objects are voltage-free and discharged.
The acoustic continuity is used to quickly check electrical circuits for continuity. If the resistance is <200 ohm, a beep
sounds. No measured value is shown.
Proceed as follows to conduct a continuity check:
- Turn the rotary switch to the measuring function
- Connect the black test lead to the COM socket (6) and the red test lead to the V/Ω
socket (7).
- Make sure that the "Vrms/Vp-p" button (9) is not pressed.
- The scale display has no function in the acoustic continuity check.
- Connect both test leads to the measuring object (component, circuit, etc.).
- If the resistance is <200 ohm, a beep sounds.
- After measurement, turn the rotary switch to position "OFF" to turn off the multimeter.
.
37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1544030

Table des Matières