WIRING
!
CAUTION: All electrical wiring should
be done by a qualified person (s) in
accordance with all applicable codes and
standards. This range hood must be
properly grounded.
Do not turn power on at service panel until
all wires have been connected.
Blower connection at hood:
1. Run conductors (2-wire plus ground) from
the exterior blower to the hood's wiring
box marked "motor connection". Fig. 6
2. Remove the cover from the wiring box
and remove one knockout. Fig. 6
3. Secure the conduit to the wiring box
through a conduit connector. Fig.6
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black
and green-to-ground. Fig.6
5. Replace the wiring box cover and screws.
Make sure wires are not pinched
between the cover and box.
Exterior blower connection:
1. Make electrical connections at the
exterior blower (see instructions provided
with the exterior blower).
Power connection at hood:
1. Run supply conductors to the hood wiring
box marked "120VAC input". Fig. 7
2. Remove the cover from the wiring box
and remove one knockout. Fig. 7
3. Secure the conduit to the wiring box
through a conduit connector. Fig. 7
4. Make electrical connections at the hood.
Connect white-to-white, black-to-black
and green-to-ground. Fig. 7
5. Replace the wiring box cover and screws.
Make sure wires are not pinched
between the cover and box.
BLOWER CONNECTION AT
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
BOX MARKED
"MOTOR
CONNECTION"
POWER CONNECTION AT HOOD
120 Volt 60Hz
LINE-IN
- 9 -
HOOD
Exterior blower
FIG. 6
CONNECT:
WHITE-TO-WHITE,
BLACK-TO-BLACK,
GREEN-TO-GROUND.
BOX
MARKED "120
VAC INPUT"