11. PREVENTIVE MAINTENANCE SCHEDULE
COMPONENT
Fuel tank
Filters
Electrodes
Fan
Combustion
chamber
12. TROUBLESHOOTING
PROBLEM
The heater does
not start or does
not operate
Smoke while
operating
The heater does
not turn off
Airchaud Diffusion - 35 route de Colmar, 67600 Sélestat
SIRET : 444 448 898 00015
MAINTENANCE FREQUENCY
Clean once a year or as required
Clean or replace once a year or as
required (make sure they are intact)
Clean or replace once a year or as
required (make sure they are intact)
Clean as required
Clean as required
Clean as required
POSSIBLE CAUSE
1. Starter switch in "OFF" (0)
position
2. No power supply
3. Power supply cable
interrupted
4. Electronic control board
blocked or malfunctioning
5. Incorrect setting of the room
thermostat (if present)
6. No fuel
7. External substances or dirt
in the fuel circuit
1. External substances or dirt
in the fuel circuit
2. Obstructed inlet air vent
1. Faulty electronic system
MAINTENANCE PROCEDURE
Empty and rinse the tank with clean
fuel (SEE PAR. 9.)
Contact a service centre
Contact a service centre
Contact a service centre
Contact a service centre
POSSIBLE SOLUTION
1. Set starter switch to "ON" (|) position (PIC.
15)
2a. Insert the power plug into the mains
socket correctly (PIC. 14)
2b. Check voltage of your electric supply
system
2c. In dual voltage models (...DV) (PIC.
9), set the switch to the correct voltage
position required
3. Contact a service centre
4a. Reset the heater (SEE PAR. 7.2.)
4b. Contact a service centre
4c. Contact a service centre
5. Set the room thermostat to a temperature
higher than the working environment
temperature (PIC. 16)
6. Top up fuel and reset heater
7c. Contact a service centre
1c. Contact a service centre
2. Remove all air vent obstructions
1. Contact a service centre
Tél. : 03 88 08 67 05
Fax : 03 88 08 67 39
contact@airchaud-diffusion.fr
www.airchaud-diffusion.fr
en
it
de
es
fr
nl
pt
da
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh
20

Publicité

Table des Matières
loading

Produits Connexes pour Sovelor HP Serie

Ce manuel est également adapté pour:

Hpv serieHp30Hp50Hp65Hp110Hpv20 ... Afficher tout

Table des Matières