Note:
1. If
appears, it means the wrench has been applied more than 110% of maximum
torque.
2. If saved more than 2000 records, the new record overwrite the last one. Please refer to the
"Peak Hold Mode Recorded Value Review" section to clear the memory records.
3. When 80% of the target is reached, the green LED will begin to flash and the alarm will
beep intermittently.
4. When 99.5% of the target torque has been reached, the buzzer will beep constantly and all
the LED will stay ON.
40
PEAK HOLD MODE OPERATION
START
(System initiate)
*Nota 1
Setting Target Torque
Released
Apply Torque
Current Torque Value
(Peak Hold)
Buzzer
Buzzer
*Nota 2
Record saved and
transmitting wirelessly
Green LED
Reached 80% of Target Torque
Red LED
Approaching Target Torque