ATTENTION:
If
appeared during power-on process, it means this wrench has been applied more than
110% of maximum torque.
AUTO POWER OFF
The wrench will auto power off after about 2 minutes idle for power saving. Press
on the wrench again.
CAUTIONS:
During communication period (wired or 2-way wireless) the auto power-off function is disabled.
ZERO RESET
-
Better Zero-reset improves the measuring accuracy. To get higher accuracy, please do
Zero-reset carefully before each measuring.
-
After power on,
-
Usually press
-
In torque mode, if an external force is applied to the torque wrench during zero-reset period,
an initial torque offset error will occur.
-
Angle Zero-Reset: Important!!!
1.
Put torque-angle wrench still horizontally on a table or workbench before angle zero-reset.
2.
In Angle mode, Press
otherwise it will start torque zero-reset.
3.
In case of successful Angle Zero-Reset, the value will keep and saved and recalled in next
power up.
RESET THE WRENCH
-
If the wrench does not function normally, please go through the reset process to reset the
wrench.
-
To reset the wrench, loosen the battery cap then tighten it to re-start. After reset, remember
to press
to power it up again.
LOW VOLTAGE INDICATOR
If the battery voltage is too low, the wrench will display a battery symbol. Please replace
batteries immediately.
28
button is for zero reset.
to zero reset the digital torque- angle wrench before measuring.
Shows
, press
again starts Angle zero-reset;
to power