Note:
1. Counting record: The counter increased when torque applied over 20% to the maximum
torque of wrench.
- This record is not erasable until re-calibration. The feature will count up to 65,000
measurements.
- Regarding the number of measurements, the following figure means the recorded count
is 10100. (No-1 means 10000 times, No-2 means 20000 times reached and so on...).
Auto Change
2. Please refer to page 29 for Header change and header length setting.
STEP 5: PEAK HOLD /TRACK MODE SELECTION
Track Mode
Long Press
Set Peack/Track mode
Press
Set Peack/Track mode
Press
Peack Hold Mode
for Selection
to quit
35