DUCTING
A minimum of 6" round ducting must be used to
Always use rigid type metal ducts only. Flexible
Use calculation worksheet to compute total duct
work.
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6" to 7" or 8".
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
Mounting height from top of cooking surface to
bottom of hood should be no less than 24" and no
more than 32".
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
mounted too high will be hard to reach and will
If available, also refer to range manufacturer's
height clearance requirements and recommended
i n .
hood mounting height above range. Always check
" m
a x .
your local codes for any differences.
" m
DAMAGE-SHIPMENT / INSTALLATION:
installation.
the unit to the store in which it was bought
for repair or replacement.
repair or replacement is the responsibility
of the customer.
replacement must be made by arrangement
between customer and installer.