English
Important!
Electrical installation:
Putting into service for the first
time:
Use
Scope of supplies
Factory-made settings
(non-changeable)
Table 1 Functions of the controlling and regulating unit BMU
Condensing boiler
G Integrated controlling and regulating unit BMU
– weather-controlled flexible regulation of boiler temperature
– modulating mode of operation
– pump heating circuit (heating circuit 1)
– hydraulic systems: application examples 1 to 3 possible
Functions of the heating circuit module HKM
G Heating circuit 1 (pump heating circuit)
– with heating circuit module HKM
• setpoint value adjustment for room temperature/boiler temperature
• button for automatic summer/winter changeover function
• weather-controlled main supply pipe temperature regulation
with proper consideration of building dynamics
• ECO functions (day heating limit switch, automatic summer/
winter changeover)
• week or day program
• quick lowering or reduced heating mode
G Water heating
– hot-water loading with absolute priority
– setpoint value adjustment for hot-water temperature
1) Operation in the case of 2 heating circuits (pump and mixer heating circuits; mixed heating system) is
possible via the room regulator device RRG or the pump heating circuit via the heating circuit module
HKM and the mixer heating circuit via the room regulator device QAA 73.
6
GB
Install the heating circuit module HKM first and then make the mains
connection.
The work must be carried out by a qualified electrician.
The adjustment details and settings in these instructions and the adjustment
details and settings in the boiler manual must be taken into account.
The heating circuit module (HKM) is intended for use in the
PARAMOUNT condensing heating.
– heating circuit module HKM
– connection cable KM-HKM
– quick lowering function active
– max. room temperature setpoint value 30°C
– min. room temperature setpoint value 10°C
– max. hot-water temperature setpoint value 60°C
– min. hot-water temperature setpoint value 8°C
Scope of supplies
Outdoor temperature sensor QAC 34
Additionally accessories
Clock timer EMS or clock timer DSU
Clock timer EMS/DSU
Clock timer EMS/DSU