Upper And Lower End Point Setting For Vertical Screens Renson; Adjusted Upper End Point; In Case Of A Retractable Bottom Bar; In Case Of A Partly Retractable Bottom Bar - Renson Somfy LS40 Mode D'emploi

Réglage des moteurs - stores verticaux
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1 • Upper and lower end point setting for
vertical screens Renson
End point setting according to factory adjustment of Renson
1
ADJUSTING UPPER AND LOWER END POINT SETTING AGAIN!
A final adjustment of the lower end point still needs to be carried out! First monitor the screen,
connect it to the power before completing the final end adjustment. The screen will move
briefly in case of an RTS or IO home engine. Please refer to the assembly manual
(included in the package) for instructions about assembling the screen.
1.1 • Adjusted upper end point:
1.1.1 • In case of a retractable bottom bar
(Fixscreen
100
®
Upper end point is adjusted in the factory and the bottom bar, including the sealing strip, is not
visible anymore. Adjust the upper end point for end use.
1.1.2 • In case of a partly retractable bottom bar
(Fixscreen
150
®
Upper end point is adjusted in the factory and the bottom bar retracts partly into the box (bottom
bar with sealing strip is partly visible). Adjust the upper end point for end use.
1.1.3 • In case of non-retractable bottom bar (Fixscreen
Fixscreen
Mono AK / Screenvent
®
Fixscreen
Mono AK
®
Upper end point is adjusted in the factory and the bottom bar joins the box as much as possible
(bottom bar with sealing strip is visible). Adjust the upper end point for end use.
End point setting - Vertical screens
®
Upper end point
Lower end point
Slim of Fixscreen
150
EVO
®
with 2,7 m < Finished height ≤ 6m)
EVO
and Screenvent
®
/ Fixvent
Mono AK
EVO
®
:
®
You have to be able to remove the front cover or
cover plate in case of surface mounted installation
or in case of hidden installation (in front/above
the window), in order to have access towards the
mechanical motor (MSM or mechanical Renson
motor). (See the installation instructions in case
of installation method 1: surface mounting with
option U-safe
) for the final motor adjustment. in
®
case of radio-controlled motor (RTS) or IO-home
motor (MSIOR) you do not need to unscrew the
front cap or cover plate.
with height 2,7m)
EVO
85 / 100 / Miniscreen
®
Mistral AK /
®
)
EVO
en
®
-range /
®
33