SETTING THE TIMER

A) HOW TO SET THE ON TIME
1. Press the SEL TYPE button once.
The ON and time indications flash.
2. Press the SET H button until the desi-
gned hour is displayed.
Press the SET M button until the desi-
gned minutes are displayed. The display
will change automatically back to show
the present time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SEL button to activate
the ON timer.
B) HOW TO SET THE OFF TIME
1. Press the SEL TYPE button twice.
The OFF and time indications flash.
2. Press the SET H button until the desi-
gned hour is displayed.
Press the SET M button until the desi-
gned minutes are displayed. The display
will change automatically back to show
the present time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SEL button two times
to activate the OFF timer.

DRAINING

When the air conditioner operates in cooling mode, it is not necessary to connect the continuous drainage of the condensate water,
except in special climatic conditions (high humidity).
To connect the continuous drainage when the air conditioner operates in COOLING MODE, switch off the unit and remove
the main plug from the supply. Remove the rubber plug from the drain pipe (A) at the bottom rear of the air conditioner and connect
a drain tube (20 mm inner diameter) for the condensate water; place the other end in a normal drain.
Make sure that the tube is free from twists and bends. The tube must decline over its entire length.
When you use the air conditioner only in dehumidification mode, instead, it is always recommended to connect the continuous
drainage in order to have maximum dehumidification efficiency.
To connect the continuous drainage when the air conditioner operates in DEHUMIDIFICATION MODE, switch off the unit and
remove the main plug from the supply. Remove the plastic ring and the rubber plug from the drain pipe (B) at the rear of the air con-
ditioner and connect a drain tube (25 mm inner diameter) for the condensate water; place the other end in a normal drain.
Make sure that the tube is free from twists and bends. The tube must decline over its entire length.
Emptying the internal water container: Occasionally it is necessary to
empty the internal water container. When the internal water container is
full the STANDBY lamp blinks.
Every time you move the unit to another room or when you store it, dis-
charge the condensate water container, through the drain pipe (A).
To empty the water container do the following actions: put a container
under the drain pipe at the bottom rear of the unit, remove the rubber
plug and allow the water to drain. Replace the rubber plug onto the drain
pipe and continue to use the air conditioner.
C) HOW TO SET A PROGRAM FOR DAILY
ON/OFF OPERATION (OR VICEVERSA)
1. Set the timer ON/OFF as shown in A)
and B).
2. Press the ON/OFF button to start the air
conditioner.
3. Press three times the TIMER SELECT
button to activate the DAILY timer.
NOTES
After timer setting, press SEL TYPE button in order to check
the ON/OFF setting time.
3
When you set the timer, the central STANDBY lamp blinks in
irregular way (when the blinking is regular indicates instead the
presence of a malfunction) and the timer indication is active on
the display of the remote controller.
SETTING THE 1 HOUR TIMER
4
1
2
This function causes the unit to operate for one hour at the set
conditions, regardless of whether the unit is on or off.
TIMER SETTING PROCEDURE.
Press four times the TIMER SEL
button.The 1 HOUR TIMER mark will
appear on the display.
CANCELLATION PROCEDURE
• Press the ON/OFF button to turn the air
conditioner off.
• Wait for the indoor unit to stop operating.
• Press the ON/OFF button again to turn the
air conditioner on.
CONTINUOUS DRAINAGE B
IN DEHUMIDIFICATION MODE
CONTINUOUS DRAINAGE A
IN COOLING MODE
EG