Zoeller 10-0229 Mode D'emploi page 4

Interrupteurs à double flotteurs superposés à niveau variable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FIGURE 8
DISCONNECT
SWITCH
WATERTIGHT
JUNCTION BOX
WHITE
GREEN
BLACK
VARIABLE
PUMP
LEVEL
FLOAT SWITCH
INSTALLATION INSTRUCTIONS, continued
6. Tape or clamp both piggyback switch and pump cords to the discharge pipe clear of float operation (see Figure 5). Excess cord should be
coiled and fastened outside the basin.
7. Clean basin of debris after installation.
8. Check your installation. Fill basin with water, and allow pump to cycle to ensure proper range and operation.
Note: Measurements as shown are approximate. Exact measurements to be determined for each individual installation.
FIGURE 9
L1
L2
L3
BLACK
WHITE
CI
CI CI
PUMP
SK306A
25
20
P/N 10-0748
15
10
5
0
5
10
(A) PUMPING RANGE IN INCHES
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 USA
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 USA
+1 (502) 778-2731 • 1-800-928-7867 • FAX +1 (502) 774-3624
© Copyright 2020 Zoeller
DISCONNECT
SWITCH
CI
BLACK
WHITE
VARIABLE
LEVEL
FLOAT SWITCH
SK378B
FIGURE 10
P/N 10-0055
P/N 10-0032
P/N 10-0033
P/N 10-0034
P/N 10-0035
P/N 10-0063
P/N 10-0559
P/N 10-0705
P/N 10-0706
15
20
25
30
These are the original installation instructions.
Co. All rights reserved.
®
4
A) Remove (cut) Piggyback Plug
from Variable Level Float Switch.
Remove approx. 3-1/2" (89 mm)
of Cord Jacket and 1" (25 mm)
insulation from Wires.
B) Wire switch into circuit as shown.
C) Return to instructions.
D) Installation must be in
accordance with the National
Electric Code and all local codes.
35
40
SK1299
visit our web site:
zoellerpumps.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

10-120910-196410-196610-023010-121010-1965 ... Afficher tout

Table des Matières