General introduction
The SK9000 unit is a stand-alone control unit with an integral reader which is used to
manage the electronic keys SK9050 and SK9052. It is used to control access to a door fitted
with an electronic lock or an automatic device.
It is supplied ready for use. It is initialised by swiping the first token over the unused unit
which then becomes the master fob to which you can then add other tokens.
Layout of the unit
The card is made up of:
- a switch used to access the programming
- three push buttons that are used to affect the parameters
- the three LEDʼs that show the statuses of the unit
- connection terminals
- a J5 firmware update connector
Description of terminals
AL: Power supply 12 - 24 V ac/dc
J1: not used
J2: NO/NC relay output
J3: exit push button
J4: integral reader
Programming modes
The S3 switch is used to switch between programming modes.
S3 in "0" position → Operating mode
S3 in "ON" position → Programming mode
N.B.: In programming mode the L2 LED and the reader LED flash rapidly.
You must go back to operating mode for the unit to manage access.
Setting the opening timer
- Turn switch S3 to "ON" (Programming)
- Press button S1 several times to adjust the time units (one press per second). Once S3 has
switched back to operating mode a double confirmation beep will validate this for you.
The minimum timing setting is 1 second.
The maximum timing setting is 99 seconds.
The unit is supplied with a 5 second opening time set by the factory.
Userʼs token management
1. Master fob.
The first token swiped in the unit will become the master fob. The green LED will flash three
times to indicate master fob creation. It will enable you to enter programming mode without
having to access the unit.
2. Adding a user token
The unit must be in OPERATING mode (switch S3 in position "0").
Pass the token in front of the reader. The LED will flash quickly (green/red) and you are in
programming mode. To add user tokens you just have to pass them in front of the reader to
register them.
To exit programming mode, pass the master fob again or wait 15 seconds without doing
anything. (The flashing will stop)
3. Partial reset - reset of Master Fob
In case the Master Fob is lost, it is possible to only reset the Master Fob in order to program
another token as Master Fob
- Turn Switch S3 to "ON" (Programming)
- Press S2 for 5 seconds, till L3 LED lights on
- Release S2
- Switch back to Operating Mode (a double beep tells you that the unit has been partially
reset)
In this moment, the first token you swipe to the reader WILL BECOME THE NEW Master
Fob
4. Complete reset
- Turn switch S3 to "ON" (Programming)
- Press S2 for 10 seconds. After 5 seconds L3 lights on ( Partial Reset ). Keep pressed 5
seconds again till L2 LED lights on ( Complete Reset )
- Release S2
- Switch back to Operating Mode ( a double beep tells you that the unit has been completely
reset )
Resetting to zero enables the initialisation process:
- the password to access the unit is "0000".
- user tokens and the master fob are deleted.
5. Deleting a token using the SK9093 kit
Using the SK9093 software, supplied separately, it is possible to display the tokens
programmed into the unit and delete them. To do this you just have to connect to the unit
using the cable supplied with the kit and launch the program.
- Click on "Token management" then "Scan the list of tokens" to display them.
-You can then either delete the user tokens: check the tokens then click on "delete the
selected token(s)" or delete the whole memory: Click on "Delete all tokens", the unit will then
be completely cleared and the first token swiped over the reader will become your master
fob.
Normal working of the unit
When the unit is in normal Operating Mode, 2 LEDs inside the units are flushing and the Red
LED on the reader is ON, flushing once briefly every 3 seconds.
If the unit is not working properly, these LEDs are giving different indications. In this case
turn the power OFF and then ON again. If this does not work, please contact our after sales
service department
Technical characteristics
• Opening time can be adjusted from between 1 and 99 seconds.
• Output via dry contact max. 5A at 250 VAC
• Power consumption: 70 mA when idle, 160 mA when relay active
• Operating temperature: -10°C - +55°C
• Operating voltage: 12 - 24 V ac/dc
• Dimensions (H X L X D): 62 x 88 x 23 mm