MAXIMUM LENGTH OF SUCTION LINES FOR TWO-PIPE SYSTEM
Two-pipe siphon feed system
H
Two-pipe lift system
H
To correct length of pipes is calculated by summing up the length of all vertical and horizontal right sections
and bends. The static suction head will be the distance between the non-return valve and the
burner's pump axle. The depression must not be greater than 0.45 bar; should it be higher, some damages
could occur to the pump, with consequent increase in mechanical noises and ,eventually, a failure.
NOZZLE
GPH
0
4.00
7,52
4.50
7,52
5.00
7,52
5.50
7,52
6.00
9,2
6.50
9,2
7.00
9,74
7.50
9,74
8.00
9,74
9.00
11,16
9.50
12
10.50
12,8
12.00
13,93
13.80
16,72
15.30
16,72
17.50
20,9
19.50
22,29
21.50
22,8
NOZZLE OUTPUT
TYPE : MONARCH F80-BPS
RETURN PRESSURE BAR
4,218
8,436
8,91
13
8,91
13
9,33
13,38
9,36
13,93
11,42
13,93
9,49
11,42
13,38
17,27
13,38
18,66
10,87
15,6
15
18,4
13,38
18,94
13,93
22,29
15
22,29
20
31,2
20
29,27
23,42
36,5
29,53
43,49
27,3
40,15
OUTPUT kg/h
11
420010251101 M ai or P 45/ 60/ 80/ 120 PR SW
H
(m)
AS 67 / AN 77
(m)
ø 10 mm ø 12 mm
0
32
0,5
36
1
40
2
48
3
56
3,5
60
H
(m)
AS 67 / AN 77
(m)
ø 10 mm ø 12 mm
0
25
0,5
21
1
18
2
10
3
5
3,5
---
12,654
16,872
19
-
21,16
-
21,39
-
25,6
30
17,8
33,45
20
36,19
24,5
39
31,2
41,82
25,64
44,55
25,64
36,77
29,53
52,9
33,7
58,55
34
66,9
57,9
76,89
43,46
72,54
66,27
-
64,6
108,74
61,28
120
Pipe length
AJ 6
(m)
ø 14 mm ø 16 mm
90
22
38
90
25
45
90
30
50
90
35
60
90
38
70
90
40
80
Pipe length
AJ 6
(m)
ø 14 mm ø 16 mm
70
25
45
62
38
20
54
33
18
38
10
20
20
10
5
10
2
4
PUMP PRESSURE
20 bar
CAPACITY kg/h
22,24
24,96
27,68
30,56
33,28
36,00
38,88
41,6
44,16
49,92
52,64
58,24
66,56
76,48
84,8
96,96
108,16
119,04
EN