Fault analysis and elimination
Fault
After the power supply is
connected and the switch is made
on, the product does not run.
There is a bad smell from the
motor in the first few times of
use of the product.
The product stops automatically
in use.
There are many residues in
juice.
The product has abnormal
vibration or big noise.
Safety indexes
220V~
50Hz
≤1 min.
≥2 min.
Standards
Possible cause
The middle ring is not correctly
installed; The top cover is not
correctly installed; or The top
cover contact has fractured.
It is normal.
The voltage is too low;
There are many food materials
in the product; The pushing rod
is pushed violently; or The
motor is under temperature
protection.
The juice strainer is damaged;
or There are many residues in
the middle ring.
The juice strainer is not correctly
installed, resulting in poor
running balance; The product is
not steadily placed or the foot
pad has fallen off; The voltage
is too high; or There are many
food materials in the product;
Elimination
Install the middle ring correctly;
Install the top cover correctly;
or Replace the top cover.
If the bad smell still exists after
the product has been used for
several times, have the product
tested by a near service center
of us.
Check whether the voltage is
too low; Disconnect the power
supply and remove the surplus
food materials; Gently push the
pushing rod; or Stop the
product and start it again 20 to
30 minutes later.
Replace the juice strainer; or
Clean the middle ring.
Install the juice strainer correctly;
Place the product steadily or
install the foot pad correctly;
Check whether the voltage is too
high; or Disconnect the power
supply and remove the surplus
food materials;