Installation - AquaScape AQUAFORCE 4000-8000 Instructions Et Entretien

Masquer les pouces Voir aussi pour AQUAFORCE 4000-8000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Always operate the pump fully submerged. Failure to do
so will overheat the pump and cause it to fail, thus voiding
the warranty. DO NOT OPERATE DRY.
• Use only in fully assembled state, and be sure that
both the upper and lower cage screens are completely
snapped together. Failure to operate the pump without the
filter cage closed will allow large debris to enter the pump,
causing the pump to fail and voiding the warranty.
• DO NOT wear loose clothing that may become entangled
in the impeller or other moving parts.
• Keep clear of suction and discharge openings. DO NOT
insert fingers into pump with power connected.
• DO NOT pump hazardous materials or liquids, such as oil,
saltwater or organic solvents.
• DO NOT block or restrict discharge.
• Products returned must be cleaned, sanitized, or
decontaminated as necessary prior to shipment. This will
ensure that employees will not be exposed to health
hazards in handling said material. All applicable laws and
regulations shall apply.
IMPORTANT: Aquascape, Inc. is not responsible
for losses, injury, or death resulting from a failure
to observe these safety precautions, misuse or
abuse of pumps or equipment.

Installation

• The AquaForce pump is designed to be submerged
directly in the pond. To maximize pond circulation, locate
the AquaForce pump as far as possible from the water
entering back into the water feature (Ex. 1).
• It is recommended that the pump NOT be positioned in
the deepest area of the pond. This will protect the fish by
preventing the pond from completely draining in the case
of a leak in the plumbing or filter. Bricks or stones can be
used, if needed, to raise the pump up off the bottom of the
pond.
• The AquaForce includes a wide assortment of fittings.
Select the appropriate fitting(s) needed for your application
(Ex 2).
4
AquaForce Pond Pump Specifications
• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
• Thermally protected
• This pump has been evaluated for use with freshwater only
• Input amps and wattage
AquaForce Adjustable Flow Solids-Handling Pond Pump Specs
Model Number
Maximum Flow Rate
Maximum Head Height
Motor Type
Wattage
Amperage
Power Cord Length
Pump Discharge Diameter
Multi-Hose Fitting Diameters
*Wattage range depending on remote control flow setting
Multi-Hose Adapter
• The threaded collar, on all of the fittings, enables the
AquaForce pump to be installed and removed without the
Ex. 1
need for any tools (Ex 3).
NOTE: Do not use tools to install the fittings to the pump
discharge. Fittings need to be only hand-tight (Ex. 4).
US (866) 877-6637 |
4000-8000
7,794
28'
Asynchronous
500 - 660*
5.5
20'
1.5" MPT
1", 1.25", 1.5", 2"
Ex.3
CAN (866) 766-3426 | aquascapeinc.com
Ex. 2
Ex. 4

Publicité

Table des Matières
loading

Table des Matières