• Remove the screws securing the pump to allow the pump
to be lifted from the lower cage.
• Remove the four screws on the pump to disconnect the
water chamber cover (Ex. 21).
NOTE: For easier pump access, pull the power cord free
from the strain relief (Ex. 22).
• Remove the impeller by pulling gently (Ex. 23)
Ex. 22

Troubleshooting

• Reduced water flow
– The pump or plumbing may be clogged
‚ Make sure nothing is blocking the intake
‚ Clean the outer cage
‚ Clean the impeller rotor assembly and internal pump
body
• Pump hums but doesn't push water
– The pump or plumbing may be clogged
‚ Make sure nothing is blocking the intake
‚ Clean the outer cage
‚ Clean the impeller rotor assembly and internal pump
body
– Make sure the pump is receiving the correct voltage
– Make sure the impeller blades are not worn or damaged
• Pump not working
– Ground-fault circuit interrupter (GFCI) may have tripped
– The pump is not receiving the correct voltage
aquascapeinc.com |
CAN (866) 766-3426 |
• Clean the impeller and internal pump body with
Aquascape Pump Cleaner Maintenance Solution (#91143),
using a sponge or soft-bristle brush.
• Re-install the impeller,
making sure the assembly
is oriented correctly and the
raised key on the impeller
face plate is lined up with
the groove in the pump
housing (Ex. 24).
NOTE: Be sure to replace
the cage and verify the
cage is not broken before operating the pump, as failure to
Ex. 21
do so may cause the pump to fail, voiding the warranty.

Winter Application

If running through winter conditions, check regularly to make
sure it is functioning properly and ice is not preventing water
from reaching the pump. In the event of a power failure, the
pump should be removed to prevent any freeze damage to
the pump or the piping.
If concerned about possible freeze damage, disconnect
and remove the pump. Be careful not to lose the flat rubber
washer. Clean with fresh water and store the pump in a
frost-free location. If needed, use Aquascape Pump Cleaner
Maintenance Solution (#91143) to remove excessive buildup.
Ex. 23
• Device won't pair
– Make sure the outlet is receiving power
– Make sure you have adequate wireless coverage to
connect the device
– Reset the device to factory defaults
– Make sure the ground-fault circuit interrupter (GFCI) is
not tripped
• Receiver displays an E1 message
– This means the input voltage going to the receiver is
greater than 142 volts. Have an electrician inspect the
outlet you have the receiver plugged into
• Receiver displays an E2 message
– Receiver is overheating - make sure the receiver is in a
shady or cooler area away from direct, intense sunlight
US (866) 877-6637
Groove
Raised Key
Ex. 24
7