Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
NO OPERATION
At the end of the calculation, the new USER K FACTOR is shown for
EN
NOTICE
a few seconds, after which the restart cycle is repeated to finally
achieve standby condition.
From now on, the indicated factor will become the
calibration factor used by the NEXT and will continue
to remain such even after a battery change
9
NO OPERATION
The NEXT stores the new work calibration factor and is ready to
begin dispensing, using the USER K FACTOR that has just been
changed.
L METER CONFIGURATION
The METER feature a menu with which the user can select the main measurement unit, Quarts (Qts), Pints
(Pts), Litres (Lit), Gallons (Gal); The combination of the unit of measurement of the Partial register and that
of the Totals is predefined according to the following table:
Combination no.
1
2
3
4
To choose between the 4 available combinations:
1
2
RESET
3
CAL
CAL
CAL
4
NOTE
18
Unit of Measurement
Partial Register
Litres (L)
Gallons (Gal)
Quarts (Qts)
Pints (Pts)
Wait for the METER to go to Standby
then press the CAL and RESET keys together. Keep these pressed un-
til the word "UNIT" appears on the screen together with the unit of
measurement set at that time (in this example Litres / Litres )
Every short press of the RESET key, the various combinations of the
units of measurements are scrolled as shown below:
By pressing the CAL key at length, the new settings will be stored,
the METER will pass through the start cycle and will then be ready to
dispense in the set units.
Gal
RESET
RESET
The Reset Total and Total registers will be automatically
changed to the new unit of measurement.
NO new calibration is required after changing the Unit of
Measurement.
Unit of Measurement
Totals Register
Litres (L)
Gallons (Gal)
Gallons (Gal)
Gallons (Gal)
Qts
Pts
Gal
RESET
M0303

Publicité

Table des Matières
loading

Table des Matières