1
General
LS31
The LS31 weld-on strain gage is mainly used for mea
surements under severe conditions on large components,
when strain gages cannot be applied by the adhesive
method. The temperature range of this strain gages is
wider than that of a strain gage installed with a cold cur
ing adhesive:
-200 °C ... +150 °C [-328 °F ... +302 °F]
1.1
Design
The LS31 strain gage consists of a Y-Series strain gage
(Constantan measuring grid encapsulated in polyimide)
which is installed on a metal carrier using EP310S hot
curing epoxy adhesive. The strain gage comes with insu
lated stranded connection wires and a silicone rubber
covering agent.
A1675-3.1 HBM: public
General
3