Rocal Habit 80 DC +T Manuel Des Caracteristiques, Installation Et Fonctionnement page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7. PROBLEMS: CAUSE AND SOLUTION
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
1. Rejects smoke and / or
insufficient draught
2. Excessive dirt on glass
3. Glass bleaching or colour
fading of the plate
4. Poor heating
5. Venting smoke and / or
gases from the front, bad
smell
6. Excessive draft
8. CE INFORMATION
The CE label is located on the appliance. This label contains technical data and OF number. (This number can also
be found in the guarantee). THIS NUMBER IS ESSENTIALFOR ORDERING SPARE PARTS.
The review of the appliance, the installation and ducts must be carried out by a professional.
WARNING:
-
All tests are carried out in observance of Regulationsm UNE-EN 13229:2002 - UNE-EN
13229:2002/A2:2005 - UNE-EN 13229:2002/AC:2006– UNE-EN 3229:2002/A2:2005/AC:2007
-
The review of the equipment, the installation and ducts must be carried out by a professional.
-
In case of doubt regarding the described herein, please contact your Rocal dealer.
-
FAILURE TO COMPLY WITH THE OBLIGATIONS DESCRIBED HEREIN OR IMPROPER
HANDLING OF THE EQUIPMENT SHALL EXONERATE THE MANUFACTURER OF ANY
LIABILITY.
In case of doubt regarding the described herein, please contact your Rocal dealer.
CAUSE
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Dirty flue duct
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive temperature caused by excessive heat in
the combustion chamber
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong position
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Incorrect duct
Combustion control registers in the wrong position
SOLUtION
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply. Simultaneous
operation with other ventilation devices and / or heating
Setting the register
Contact a professional to clean flue duct. If the problem
persists, contact your dealer.
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
Check the fuel load avoiding overheating
Adjust registers
Use recommended fuel
Adding fuel
Adjust registers
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
12

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Habit 100 dc +t

Table des Matières