Service And Adjustments - Craftsman 919.724591 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

when power is on. When doing
Maintenance, you may be exposed
to voltage sources, compressed air
or moving parts. Personal injuries
can occur. Before performing any
Maintenance or repair, unplug the
compressor and bleed off all air
pressure.
ALL MAINTENANCE AND REPAIR
OPERATIONS NOT LISTED MUST
BE PERFORMED BY TRAINED
SERVICE TECHNICIAN.
Unplug or disconnect electrica
supply to the air compressor.
Bleed tank of pressure.
Allow the air compressor to
cool.
To Replace or Clean Check
Valve
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Remove the regulator ring and
remove the console cover.
Regulator
Ring
4.
Remove shrouds.
5.
Using an adjustable wrench
loosen outlet tube nut at air tank
and pump. Carefully move outlet
tube up away from check valve.
A14841

SERVICE AND ADJUSTMENTS

Unit cycles
automatically
Before servicing:
Cover
Outlet Tube
Pressure
Relief
Tube
Nut
6.
Using an adjustable wrench
loosen pressure relief tube nut
at air tank and pressure switch.
Carefully move pressure relief
tube away from check valve.
7.
Unscrew the check valve (turn
counterclockwise) using a 7/8"
open end wrench. Note the
orientation for reassembly.
8.
Using a screwdriver, carefully
push the valve disc up and
down. NOTE: The valve disc
should move freely up and down
on a spring which holds the valve
disc in the closed position, if
not the check valve needs to be
cleaned or replaced.
In open
position
nothing is
visible.
9.
Clean or replace the check
valve. A solvent, such as paint or
varnish remover can be used to
clean the check valve.
10. Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
11. Replace the pressure release
tube. Tighten nuts.
18- ENG
Nut
Check
Valve
Screwdriver
In closed position
disc is visible.

Publicité

Table des Matières
loading

Table des Matières