Installation Instructions; Tools And Parts; Location Requirements - Whirlpool 8578198C Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tools and Parts

Tools needed
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Flat-blade screwdriver
Level
Adjustable wrench
Vent clamps
Parts supplied
Remove parts package from the dryer drum. Check that all parts
listed are included.
1 - Cycle Control (timer)
knob
1 - Push to Start button
4 - casters
Parts needed
Check local codes, existing electrical supply and venting, and
see "Venting Requirements" and "Electrical Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system
hardware
Permanent installations require 4 dryer feet
For ordering information, please reference the "Assistance or
Service" section of this manual. You can also contact the dealer
from whom you purchased your dryer.

Location Requirements

You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A 120-volt, 60-hz., AC-only, 15- or 20-amp circuit.
4

INSTALLATION INSTRUCTIONS

Caulking gun and
compound (for installing
new exhaust vent)
Tin snips (new vent
installations)
2 - cord brackets
2 - screws
A grounded electrical outlet located within 2 ft (610 mm)
of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the dryer weight (dryer and load)
of 115 lbs (52 kg). The combined weight of a companion
appliance should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
†Height with caster is 32½" (826 mm)
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbows. See "Venting
Requirements."
Minimum installation spacing for recessed area and closet
installation
The following dimensions shown are for the minimum spacing
allowed when the unit is to be operated with, or without, the
Stack Stand Kit. To purchase a Stack Stand Kit, see "Assistance
or Service."
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
20
3
"
*
4
(527 mm)
31"
(787 mm)
7
23
"
8
(606 mm)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ldr3822pqLdr3822p