Locating and Grounding the Chassis

Locating and Grounding the Cisco ONS 15310-MA ANSI and ONS 15310-MA ETSI Chassis,
page 19
Locating and Grounding the Cisco ONS 15310-CL ANSI Chassis, page 21
Locating and Grounding the Cisco ONS 15600 ANSI and ONS 15600 ETSI Bay Assembly,
page 23
Warning
This equipment is intended to be grounded. Ensure that the host is connected to earth ground during
normal use. Statement 39.
Warning
Use copper conductors only. Statement 1025.
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last. Statement 1046.
A #6 AWG cable or a 1 inch wide flat copper braid (with minimum total strands count of 1050 x 36 AWG
Note
or 260 x 36 AWG) is mandatory to install the Cisco ONS 15454 M2, ONS 15454 M6,
ONS 15454 ANSI, ONS 15454 ETSI, ONS 15310-MA ANSI, ONS 15310-MA ETSI,
ONS 15310-CL ANSI, ONS 15600 ANSI, and ONS 15600 ETSI chassis.

Locating and Grounding the CPT 50 Shelf

Before locating and grounding the CPT 50 shelf, you must complete the prerequisites mentioned in
"Prerequisites" section on page
shelf:
Verify that the office ground cable is connected to the top of the bay and the office ground, according to
Step 1
local site practice. (See
The CPT 50 installations are suitable for Network Telecommunication facilities and locations where
Note
NEC applies.
Note
Additional ground cables may be added depending on local site practice. The CPT 50 shelf is designated
only for a Common Bonding Network (CBN), according to the GR-1089-CORE Issue 5 (sec 9.3)
definitions.
Note
The DC power battery return (BR) terminal or positive terminal must be grounded at the source end
(power feed or DC mains power end). The DC power BR input terminal is not connected to the
equipment frame (chassis), so it is configured as DC-1 according to the GR-1089-CORE, Issue 5
(sec 9.8.3) definitions.
Electrostatic Discharge and Grounding Guide for Cisco CPT and Cisco ONS Platforms
8
3. To locate the ground point and attach a ground cable to the CPT 50
Figure 1
and
Figure
2.)
78-18960-03