Craftsman 919.724271 Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Use pipe that is the same size as
the air tank outlet. Piping that is
too small will restrict the flow of
air.
If piping is over 100 feet long,
use the next larger size.
Bury underground lines below
the frost line and avoid pockets
where condensation can gather
and freeze. Apply pressure
before underground lines are
covered to make sure all pipe
joints are free of leaks.
FEEDER LINES SLOPE
AIR FLOW
MAIN DISTRIBUTION AIR LINES
Slope pipe in direction of air flow.
Water condensate flows along
bottom of pipe to drain legs,
preventing it from entering feeder
lines.
LUBRICATOR
MOISTURE
SEPARATOR
AND TRAP
DIRT
LEG
TYPICAL COMPRESSED
AIR DISTRIBUTION SYSTEM
D25050
WITH AIR FLOW
REGULATOR
DRAIN
TRAP
A flexible coupling is
recommended to be installed
between the air discharge outlet
and main air distribution line to
allow for vibration.
A separate regulator is
recommended to control the air
pressure. Air pressure from the
tank is usually to high for
individual air driven tools.
AIR FLOW
AIR USAGE
LINES
DIRT
LEG
FILTER
FLEXIBLE
COUPLING
AIR DISCHARGE
VALVE
DRAIN COCK
VALVE
12- ENG
DRAIN
LEGS
DRAIN
TRAPS
REGULATOR
LUBRICATOR
AIR
COMPRESSOR

Publicité

Table des Matières
loading

Table des Matières