IIALATAP 1 - Ed.6 - April 2012
INSTALLATION INSTRUCTIONS
for 9000 series AL - ALE - A2L- AT 2/3 - AP 2/3 pumps
INSTALLATIONSHINWEISE
für 9000er Modellreihen der AL - ALE - A2L - AT 2/3 - AP 2/3 Pumpen
NOTICE D'INSTALLATION
pour pompes AL - ALE - A2L- AT 2/3 - AP 2/3 séries 9000
ISTRUZIONI PER L'INSTALLAZIONE
per pompe AL - ALE - A2L - AT 2/3 - AP 2/3 serie 9000
SUNTEC INDUSTRIES FRANCE - 1, rue Lavoisier - BP 102 - F-21603 LONGVIC Cedex
Tel. +33 (0)3 80 70 60 70 - Fax +33 (0)3 80 70 61 11 - www.suntec.fr

Publicité

loading

Sommaire des Matières pour SUNTEC insight AL Serie

  • Page 1 AL - ALE - A2L - AT 2/3 - AP 2/3 serie 9000 SUNTEC INDUSTRIES FRANCE - 1, rue Lavoisier - BP 102 - F-21603 LONGVIC Cedex Tel. +33 (0)3 80 70 60 70 - Fax +33 (0)3 80 70 61 11 - www.suntec.fr...
  • Page 2 Pumps with the letter "P" in the pump code (eg. AL 35 C 9528 6P 0500) are models (the shaft seal can be damaged) - contact Suntec. supplied for 2-pipe operation (the by-pass plug bp is fitted in the return port R).
  • Page 3 WARNING If the pressure required cannot be obtained , check that the pump is For AT3 and AP3 pumps, the cover pressure port Ps gives only pressure in completely purged. If air bubbles are found in the fuel, check all connections high mode.
  • Page 4 AL / ALE CONNECTIONS Figures are for "C" rotation and nozzle outlet. : suction G 1/4 : nozzle outlet G 1/8 : return G 1/4 : vacuum gauge port G 1/8 : pressure gauge port G 1/8 : special pressure port G 1/8 (low mode = dumping pressure - high mode = nozzle pressure) : pressure adjustment (A1 = low pressure - A2 = high pressure) : blocking solenoid valve for cut-off...
  • Page 5 One pipe siphon feed system Nozzle*/Düse* Einstranginstallation - Tank höher als Pumpe Gicleur*/Ugello* 0,50 0,60 0,80 1,00 1,50 2,00 4,00 6,00 9,50 Installation monotube en charge (US GPH) Impianti monotubo a sifone d (mm) H (m) 131 109 150 10 109 150 150 12 127 150...
  • Page 6: Pipe Dimensions

    PIPE DIMENSIONS Rated speed : 2850 rpm - Viscosity : 5 cSt - Pressure : 9 bars The annexed charts give the maximum length (in meters) of suction line as a function of 3 variables : lift between fuel unit and tank (H), nozzle capacity or pump type,pipe diameter (d), for an altitude of 200 m above sea level and 0,45 bars vacuum.