Sommaire des Matières pour SUNTEC insight AL Serie
Page 1
AL - ALE - A2L - AT 2/3 - AP 2/3 serie 9000 SUNTEC INDUSTRIES FRANCE - 1, rue Lavoisier - BP 102 - F-21603 LONGVIC Cedex Tel. +33 (0)3 80 70 60 70 - Fax +33 (0)3 80 70 61 11 - www.suntec.fr...
Page 2
Pumps with the letter "P" in the pump code (eg. AL 35 C 9528 6P 0500) are models (the shaft seal can be damaged) - contact Suntec. supplied for 2-pipe operation (the by-pass plug bp is fitted in the return port R).
Page 3
WARNING If the pressure required cannot be obtained , check that the pump is For AT3 and AP3 pumps, the cover pressure port Ps gives only pressure in completely purged. If air bubbles are found in the fuel, check all connections high mode.
Page 4
AL / ALE CONNECTIONS Figures are for "C" rotation and nozzle outlet. : suction G 1/4 : nozzle outlet G 1/8 : return G 1/4 : vacuum gauge port G 1/8 : pressure gauge port G 1/8 : special pressure port G 1/8 (low mode = dumping pressure - high mode = nozzle pressure) : pressure adjustment (A1 = low pressure - A2 = high pressure) : blocking solenoid valve for cut-off...
Page 5
One pipe siphon feed system Nozzle*/Düse* Einstranginstallation - Tank höher als Pumpe Gicleur*/Ugello* 0,50 0,60 0,80 1,00 1,50 2,00 4,00 6,00 9,50 Installation monotube en charge (US GPH) Impianti monotubo a sifone d (mm) H (m) 131 109 150 10 109 150 150 12 127 150...
PIPE DIMENSIONS Rated speed : 2850 rpm - Viscosity : 5 cSt - Pressure : 9 bars The annexed charts give the maximum length (in meters) of suction line as a function of 3 variables : lift between fuel unit and tank (H), nozzle capacity or pump type,pipe diameter (d), for an altitude of 200 m above sea level and 0,45 bars vacuum.
Ce manuel est également adapté pour:
Insight ale serieInsight a2l serieInsight at 2/3 serieInsight ap 2/3 serieInsight al 9000Insight ale 9000...
Afficher tout
Insight a2l 9000Insight at 2/3 9000Insight ap 2/3 9000