OPTIONS AND ACCESSORIES
Alternate Dispensing Volumes
A unit option is available that has alternate, premeasure
dispensing volumes. These volumes are indicated on the
control panel label.
For the alternate version, the three Volume Selection buttons
underneath the display dispense at premeasure quantities of
1.5QT, 2QT, and 8QT.
• 1.5QT = 1.5 quarts (1.4 liters)
• 2QT = 2 quarts (1.9 liters)
• 8QT = 8 quarts (7.6 liters)
• The red button dispenses and stops water manually.
NOTE: The dispense amounts can be adjusted if required. See
"Programming The Dispenser" in the OPERATION
section.
Wall Mount Installation
A wall-mounted shelf is available for installations that require
the unit to be mounted on a wall. mounting the unit on a wall
requires special considerations and procedures due to the
weight of the unit. Follow the guidelines below when
determining the location for wall mounting as well as during
installation.
NOTE: Unit weight filled with water capacity (12 gallons
[45 liters]) is 180 lbs. (82 kg).
• The wall shelf must be fastened to a wall with 16"
(406 mm) on center, solid wood 2x4 stud construction
covered by a minimum of 1/2" (13 mm) thick sheathing.
• The wall shelf must be installed with six lag screws that are
a minimum of 3/8" (9.5 mm) in diameter and 3" (76 mm)
long. The screws must solidly hit the wood studs in the
wall.
• make sure the unit is at the proper height in an area
convenient for use.
Parts Included
The following parts are included with wall-mounted units.
Installation Procedure
Use the following procedure to install a wall-mounted unit.
1. make sure the mounting location meets the requirements
2. Determine the height for the unit installation.
Power I/O
3. Locate the wood stud positions in the wall.
(on/off) Switch
Water
4. Install the wall shelf onto the wall.
Temperature
Display
Volume
Selection
Buttons
Manual
Dispense
Button
5. Lift the unit and set it on the wall shelf with the rear legs
6. Refer to the INSTALLATION section in this manual to
7. Plug the unit into a properly grounded electrical receptacle of
14
Item
Wall Shelf
Lag Screw, 3/8" x 3" (9.5 x 76 mm) 6
Flat Washer
listed previously in this procedure.
• mark the wall at the desired height for the top of the shelf.
• Determine which studs to use for installation. The studs
used must allow the wall shelf to be installed with the
mounting holes a distance of 16" (406 mm) on center
from each other.
a. Center and level the wall shelf on the desired studs.
mark the locations for the six lag screws through the
holes in each side of the shelf.
b. Drill six 15/64" (6 mm) pilot holes in the wall at each
marked location for the lag screws. The lag screws must
be a minimum of 3/8" (9.5 mm) in diameter and 3"
(76 mm) long.
c. Insert six lag screws with flat washers through the wall
shelf and into the pre-drilled pilot holes in the wall.
d. Tighten each lag screw securely.
Lag
Lag
Screw
Screw
Flat
Flat
Flat
Washer
Washer
Washer
Cutout for power
Cutout for power
cord/drain hose.
cord/drain hose.
Rear Leg
Rear Leg
Retainer
Retainer
Wall Shelf
Wall Shelf
Attaching the Wall Shelf
securely behind the rear leg retainer. This step may require
two people.
complete the water connection to the unit
the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
English
Quantity
1
6
1/2" (13 mm)
Sheathing
2 x 4 W o o d
2 x 4 W o o d
S t u d s 1 6 "
S t u d s 1 6 "
( 4 0 6 m m )
( 4 0 6 m m )
O n C e n t e
O n C e n t e
r
r
Form No. AWDm-1016