ASSEMBLY & INSTALLATION INSTRUCTIONS
Note: This product is labeled of outdoor use only and
should be operated outdoors. It is not recommended to
operate indoors. If under certain conditions that make
it impossible to operate outdoors you can operate
indoor using a hood vent or venting. Venting can cause
restriction of air flow through the combustion chamber
causing excessive soot. Use a larger vent size then the
exhaust stack to prevent restriction and contact the
local servicing dealer to adjust the air mixture after
installation of vent.
Spray Gun, Spray Lance, Nozzle and High
Pressure Hose Installation
Note: The EASY!Lock system joins components with a
quick-fasten thread solidly and securely with just one turn.
Join the spray lance with the trigger gun and tighten until
hand-tight (EASY!Lock).
Mount the nozzle on the spray lance (marking on the
adjustment ring at the top) and hand-tighten it (EASY!Lock).
Join the high-pressure hose with trigger gun and high-
pressure connection of the appliance and tighten until
hand-tight (EASY!Lock).
1
IMPORTANT: If the pressure washer has not been used
for an extended period of time, remove the nozzle from
the end of the wand and turn on water supply. Allow
water to run from the end of the wand until clear.
IMPORTANT: The trigger gun provided with this
pressure washer is equipped with a manual trigger
lock to prevent accidental operation of the trigger gun.
The trigger lock should be used whenever the trigger
gun is not in use.
Opening/Closing The Trigger Gun
 • To open the trigger gun: Actuate the safety lever and
trigger.
 • To close the hand spray gun: Release the safety lever
and trigger.
10
Replace The Nozzle
DANGER: Risk of injury! Switch the appliance off prior
to replacing nozzle and activate hand spray gun until
device is pressureless.
 • Secure the trigger gun. To do so, push the safety catch
towards the front.
 • Replacing the nozzle
Electrical
This machine, when installed, must be electrically
grounded in accordance to local codes. Check for proper
power supply using a volt meter.
WARNING: Make sure all switches and controls are in
the OFF position prior to plugging in.
For connection values, see technical data and type plate.
The electrical connections must be done by an electrician
according to NEC and local codes.

GFCI Instructions

STEP 1: Plug the Ground Fault Circuit Interrupter (GFCI)
into a working outlet.
STEP 2: Press ''TEST'', then press ''RESET'' to assure
proper connection to power.
Note: The actual appearance of the GFCI may be different
from this illustration.
1
2
Fuel Refill
DANGER: Danger of explosion! Only refill diesel oil
or light fuel oil. Inappropriate fuels, e.g. petrol, must
not be used.
DO NOT USE GASOLINE, CRANKCASE OIL RESIDUALS
OR WASTE OIL.
ATTENTION: Risk of damage! Never operate device
with an empty fuel tank. The fuel pump will otherwise
be destroyed.
 • Refill fuel.
 • Close tank lock.
 • Wipe off spilled fuel.