WHITE-RODGERS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This control is a dual-function control having a tempera-
ture regulating control in series with a high-limit control.
The temperature control is a SPDT switch which opens on
a rise in temperature and will control one or two heating
elements.
THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the White-
Rodgers warranty.
WARNING
!
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.
AC ELECTRICAL RATINGS
UL and CSA recognized for resistive loads.
Temp Control
Voltage
30 amps
120-250 VAC
25 amps
277 VAC
12.5 amps
480 VAC
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
The limit control is a normally closed DPST switch which
opens on a rise in temperature to limit the maximum
allowable temperature. It has manual reset.
Both switches are calibrated to meet the requirements for
typical residential type storage tank water heaters.
Temperature Ratings:
Limit Control
40 amps
40 amps
25 amps
Printed in U.S.A.
756-50
Electric Water Heater Control
INSTALLATION INSTRUCTIONS
CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.
Following installation or replacement, follow
appliance manufacturers' recommended instal-
lation/service instructions to insure proper op-
eration.
Temperature control - Variable 90° to 150°F (32° to
Limit control - Fixed 170°F (77°C) with manual reset
DESCRIPTION
PRECAUTIONS
SPECIFICATIONS
66°C)
PART NO. 37-5785A
9714

Publicité

loading

Sommaire des Matières pour Emerson White-Rodgers 756-50

  • Page 1 Voltage Limit Control 30 amps 120-250 VAC 40 amps 25 amps 277 VAC 40 amps 12.5 amps 480 VAC 25 amps WHITE-RODGERS DIVISION PART NO. 37-5785A EMERSON ELECTRIC CO. Printed in U.S.A. 9797 REAVIS ROAD 9714 ST. LOUIS, MISSOURI 63123-5398...
  • Page 2 INSTALLATION Wiring All wiring must conform to local and national electrical codes and ordinances. Connect in accordance with wiring diagrams provided by the equipment manufacturer. If none are provided, the following represents a typical installation. Wiring Diagram for Typical Two-Element Residential Electric Storage Water Heater, Non-Simultaneous Operation.
  • Page 3: Précautions

    30 A 120-250 V 40 A 25 A 277 V 40 A 12,5 A 480 V 25 A WHITE-RODGERS DIVISION No. DE PIÉCE 37-5785A EMERSON ELECTRIC CO. Imprimé aux États-Unis 9797 REAVIS ROAD 9714 ST. LOUIS, MISSOURI 63123-5398...
  • Page 4: Réglage Du Cadran

    INSTALLATION Branchements Tous les branchements doivent être conformes aux codes et règlements électriques locaux et nationaux. Brancher selon les schémas fournis par le fabricant de l’équipement. Si aucun n’est fourni, les schémas suivants représentent une installation typique. Schéma de branchement pour chauffe-eau à ballon résidentiel typique à...
  • Page 5 Control de límite - Fijo 77°C (170°F) con reajuste Temperatura de Límite manual 30Amp 120-250V 40Amp 25Amp 277V 40Amp 12,5Amp 480V 25Amp WHITE-RODGERS DIVISION No. DE PARTE 37-5785A EMERSON ELECTRIC CO. Impreso en EE.UU. 9797 REAVIS ROAD 9714 ST. LOUIS, MISSOURI 63123-5398...
  • Page 6 INSTALACION Cableado Todo el cableado tiene que cumplir con las regulaciones y los códigos eléctricos nacionales y locales. Conéctelo según los diagramas de cableado ofrecidos por el fabricante del equipo. Si no viene ninguno incluido, a continuación se presenta una instalación típica. Diagrama de Cableado para Calentadores de Agua, de Dos Elementos, Típicos, de Almacenamiento, Eléctricos, Residenciales,...