Triton TMNRTR Instructions D'utilisation Et Consignes De Sécurité page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Contact
For technical or repair service advice, please contact the helpline
toll free: 855-227-3478
Web: tritontools.com/en-GB/Support
Address:
Toolstream Inc.
380 Crompton St
Charlotte
NC 28273
Storage
Store this tool in the supplied case, in a secure, dry location out of the
reach of children
Disposal
Always adhere to national regulations when disposing of power tools that are no longer
functional and are not viable for repair.
Do not dispose of power tools, or other waste electrical and electronic equipment
(WEEE) with household waste
Contact your local waste disposal authority for information on the correct way to
dispose of power tools
Troubleshooting
Problem
Possible Cause
Inaccurate cutting
Depth Stop (30) /
profile
depth (Trimmer Base)
not correctly adjusted
Incorrectly fitted or
Bit/Collet/Collet Nut
Router (1) will not
No supply of power
operate
Brushes worn or
ON/OFF Switch (10) is
Router does not start
Motor components
when ON/OFF Trigger
faulty or short circuited
Switch is pressed
Router runs or cuts
Blunt or damaged
slowly
cutter/Router Bit
Disc is off
Speed Dial (11) set
centre/vibrating
eccentrically
Motor is overloaded
Excessive vibration
Incorrectly fitted or
loose Router Bit
Bent or damaged
tritontools.com
Solution
Ensure the Depth
Stop/trimmer height
corresponds to the
maximum amount of
cut permitted by the
Depth Turret (31) /
Trimmer Depth Micro
Adjustment Dial (46)
Tighten Router
loose Router
Bit/Collet/Collet Nut
and cutter assembly
(48, 3 or 17)
Check that power is
available at source
Disconnect power,
sticking
open Brush Access
Covers (12) and
ensure brushes are
not damaged or
heavily worn. If worn,
replace brushes (see
'Brushes' or have the
tool serviced by an
authorised Triton
service centre)
Have the tool serviced
faulty
by an authorised
Triton service centre
Have the tool serviced
by an authorised
Triton service centre
Re-sharpen or replace
cutter/Router Bit
Increase variable
low
speed setting
Reduce pushing force
on Router
Re-fit or tighten Router
Bit and Collet Nut (17)
Replace Router Bit
Router Bit
Heavy sparking occurs
Brushes not moving
inside motor housing
Micro Winder (20)
"clicks" or not
adjusting on Plunge
Damaged or worn
Base (9)
Plunge Lock Lever
(24) engaged
Incorrect blade
Blocked motor
housing vents
Guarantee
To register your guarantee visit our web site at
tritontools.com* and enter your details.
Purchase Record
Date of Purchase:
___ / ___ / ____
Model: TMNRTR
Retain your receipt as proof of purchase
Triton Precision Power Tools guarantees to the purchaser of this product that if
any part proves to be defective due to faulty materials or workmanship within 3
YEARS from the date of original purchase,
Triton will repair, or at its discretion replace, the faulty part free of charge.
This guarantee does not apply to commercial use nor does it extend to normal
wear and tear or damage as a result of accident, abuse or misuse.
* Register online within 30 days.
Terms & conditions apply.
This does not affect your statutory rights
Original Instructions
Disconnect power,
freely
remove brushes, clean
or replace (see
'Brushes')
Have the tool serviced
motor
by an authorised
Triton service centre
Release Plunge Lock
Lever
Check the blade is the
correct type for the
material to be cut
Clear vents e.g. using
compressed air
18