Step 2: Install Humidifier - Honeywell Home HE120 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Select a location for the Humidistat.
• Humidistat can be mounted on the return duct or
on the wall in the main living space. (Return duct
mounting is easiest for installing wiring.)
• For return duct mounting, the Humidistat must
be mounted upstream from the Humidifier and
Bypass Collar so it is properly sensing the relative
humidity of the house. See Fig. 3.
• Locate the control at least 8 in. upstream from the
Humidifier or Bypass Collar in the return air duct.
ALTERNATE LOCATION
RETURN
AIR
6 in. (152 mm)
MINIMUM
BEST
LOCATION
RETURN AIR DUCT
Fig. 3. Selecting duct location for
Humidistat and Humidifier.
4. Select a water supply location
• Use either hard or soft water in the Humidifier.
• Use either hot or cold water in the Humidifier.
• Make sure 20 ft. of Plastic Water Tubing is long
enough to connect the water supply (saddle
valve) to the Humidifier.
• Make sure saddle valve is accessible after
installation.
5. Locate 120V Electrical Outlet.
• Select a location with access to an outlet. If an
outlet is not available, contact an electrician to
have one installed.
• Make sure the 20 ft. of Thermostat Wire is
adequate to reach from the Humidifier motor to
the Humidistat, and the Humidistat to the Plug-in
Transformer.
6. Locate Closest Floor Drain.
• Select location with access to floor drain, if
available.
• Overflow drain is required in applications where
water overflow could cause flooding or property
damage.
• If an overflow drain is needed, make sure
Overflow Tubing is long enough to reach from the
Humidifier to the floor drain.
RETURN
AIR
15 in. (381 mm)
MINIMUM
8 in. (203 mm)
MINIMUM
M13611A
5
HE120 BY-PASS DRUM HUMIDIFIER
NOTE: Every installation is unique. Please ensure that
water, power, and drain are available before
installing the device. In some cases, additional
wire, tubing, or duct may need to be purchased in
order to correctly install the Humidifier.

STEP 2: INSTALL HUMIDIFIER

WARNING
Hazardous Voltage.
Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning or
electrical accessory.
CAUTION
Sharp Edges Installation Hazard.
Can cause personal injury.
Wear gloves and safety glasses.
1. Turn off power to heating and cooling system.
2. Draw a level line on the duct in the location chosen
for the Humidifier. (Leveling assures optimal perfor-
mance.) See Fig. 4.
NOTE: There must be at least 1-1/2 in. of duct above the
line and 8-1/2 in. of duct below the line for proper
installation. The duct must also be at least 11 in.
wide for proper installation.
Fig. 4. Marking template location.
3. Cut out template on page 22.
4. Tape template in position and trace around the tem-
plate with a marker.
5. Remove the template and carefully cut the rectan-
gular opening using tin snips. See Fig. 5. (Use a drill
to start the cut in the middle of the rectangle.)
69-1860EF—02