HE120 By-pass Drum Humidifier
INSTALLATION INSTRUCTIONS
Contents
Unpacking the Unit ..................................................................................................................................................................................................... 2
Before You Begin ......................................................................................................................................................................................................... 4
STEP 1: Determine Best Location ......................................................................................................................................................................... 4
STEP 2: Install Humidifier ........................................................................................................................................................................................ 5
STEP 3: Install Bypass Collar .................................................................................................................................................................................. 7
STEP 4: Install Bypass Duct .................................................................................................................................................................................... 9
STEP 5: Assemble Humidifier Drum .................................................................................................................................................................... 10
STEP 6: Assemble Humidifier ................................................................................................................................................................................. 11
STEP 7: Install Drain ................................................................................................................................................................................................... 13
STEP 8: Install Saddle Valve .................................................................................................................................................................................... 13
STEP 9: Install Water Line ........................................................................................................................................................................................ 15
STEP 10: Install Humidistat .................................................................................................................................................................................... 16
STEP 11: Wiring ............................................................................................................................................................................................................ 19
STEP 12: Testing and Checkout ............................................................................................................................................................................. 20
69-1860EF-02

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell Home HE120

  • Page 1: Table Des Matières

    HE120 By-pass Drum Humidifier INSTALLATION INSTRUCTIONS Contents Unpacking the Unit ........................................2 Before You Begin ......................................... 4 STEP 1: Determine Best Location ..................................4 STEP 2: Install Humidifier ......................................5 STEP 3: Install Bypass Collar ....................................7 STEP 4: Install Bypass Duct ....................................9 STEP 5: Assemble Humidifier Drum ..................................
  • Page 2: Unpacking The Unit

    HE120 BY-PASS DRUM HUMIDIFIER UNPACKING THE UNIT This box contains all of the parts necessary to install your new HE120 Humidifier in most installations. Before continuing, please take the time to familiarize yourself with these components. • Humidifier Housing • Motor Plate •...
  • Page 3 HE120 BY-PASS DRUM HUMIDIFIER • Open Drum End • Closed Drum End U 18-gauge two-strand thermostat wire (20 ft.) V 1/4 in. plastic water tubing (20 ft.) W 3/8 in. inside diameter, 1/2 in. outside diam- eter plastic Overflow Tube (10 ft.) [Not •...
  • Page 4: Before You Begin

    HE120 BY-PASS DRUM HUMIDIFIER BEFORE YOU BEGIN When Installing this Product… 1. Read these instructions carefully. Failure to follow NOTE: The Bypass Duct can be connected to either side them could damage the product or cause a hazard- of the Humidifier Housing. See Fig. 2.
  • Page 5: Step 2: Install Humidifier

    HE120 BY-PASS DRUM HUMIDIFIER 3. Select a location for the Humidistat. NOTE: Every installation is unique. Please ensure that • Humidistat can be mounted on the return duct or water, power, and drain are available before on the wall in the main living space. (Return duct installing the device.
  • Page 6 Water Pan, and Motor Plate. 7. Position the HE120 Humidifier Housing over the opening (make sure it is level) and mark the five mounting holes. See Fig. 6.
  • Page 7: Step 3: Install Bypass Collar

    HE120 BY-PASS DRUM HUMIDIFIER STEP 3: INSTALL BYPASS 2. Trace around the inside of the collar and mark the location of the mounting holes with a marker. COLLAR 3. Remove the collar and carefully cut out the circular opening using tin snips. See Fig. 9. (Use a drill to start the cut in the middle of the circle.
  • Page 8 HE120 BY-PASS DRUM HUMIDIFIER 4. Pre-drill the mounting holes using a 1/8 in. drill bit. 5. If you are installing the Optional Damper, place a #8 If you are installing the optional Damper, do not drill X 3/4 in. Sheet Metal Screw through the Bypass Col- the hole where the damper blade will swing.
  • Page 9: Step 4: Install Bypass Duct

    HE120 BY-PASS DRUM HUMIDIFIER STEP 4: INSTALL BYPASS 3. Secure Bypass Duct to Humidifier using at least three #8 x 3/4 in. Sheet Metal Screws. See Fig. 14. DUCT Drill pilot holes using 1/8 in. drill bit.) CAUTION Sharp Edges Installation Hazard.
  • Page 10: Step 5: Assemble Humidifier Drum

    HE120 BY-PASS DRUM HUMIDIFIER STEP 5: ASSEMBLE 3. Slide Humidifier Pad over closed drum end posts. See Fig. 18. HUMIDIFIER DRUM 1. Slide Closed Drum End over Drum Shaft with round posts facing away from metal tabs. See Fig. 16.
  • Page 11: Step 6: Assemble Humidifier

    HE120 BY-PASS DRUM HUMIDIFIER STEP 6: ASSEMBLE 5. Place motor lead wires through bottom hole of Motor Cover and snap into place on outside of HUMIDIFIER Humidifier. See Fig. 22. 1. Position the Bearing Bracket inside the Humidifier Housing to the side where the Bypass Duct is con- nected.
  • Page 12 HE120 BY-PASS DRUM HUMIDIFIER DRAIN FITTING FLOAT MOTOR FLOAT VALVE M13626 M13628 Fig. 24. Correct Float Valve position. Fig. 27. Installing Drain Fitting. HUMIDIFIER 9. Place the Water Pan in the Humidifier Housing so HOUSING WALL Overflow Tube is above previously installed Drain Fitting.
  • Page 13: Step 7: Install Drain

    HE120 BY-PASS DRUM HUMIDIFIER IMPORTANT STEP 7: INSTALL DRAIN Do not turn handle before or while installing the saddle valve. Be sure the piercing lance does not protrude beyond the rubber gasket. Failure to do CAUTION this may damage piercing needle.
  • Page 14 HE120 BY-PASS DRUM HUMIDIFIER a. For 3/8 in. diameter copper tubing use bracket 3. Turn the handle to expose the lance beyond the gas- side with projections to prevent distorting tube. ket no more than 3/16 in. See Fig. 34.
  • Page 15: Step 9: Install Water Line

    HE120 BY-PASS DRUM HUMIDIFIER STEP 9: INSTALL WATER LINE 2. Slide the Plastic Compression Sleeve over the Tub- ing. 3. Install Brass Insert into end of Plastic Water Tubing. CAUTION NOTE: To prevent leaking, use Plastic Compression Sleeve only with Plastic Tubing and Copper Com- Water Hazard.
  • Page 16: Step 10: Install Humidistat

    HE120 BY-PASS DRUM HUMIDIFIER STEP 10: INSTALL 3. Refer to Fig. 37, and use the following steps to cut the Humidistat mounting hole. HUMIDISTAT a. Drill a 1/2 in. hole in the center of the template. b. Use tin snips to cut the opening along the dotted lines.
  • Page 17: Wall Mounting

    HE120 BY-PASS DRUM HUMIDIFIER 5. Unscrew Back Cover of the Humidistat and remove. 9. Use four #6 x 1 in. Sheet Metal Screws to secure the See Fig. 39. assembly to the duct through the mounting holes. See Fig. 42.
  • Page 18: Baseplate

    HE120 BY-PASS DRUM HUMIDIFIER 5. Unscrew the Back Cover of Humidistat and remove. See Fig. 39. WALL 6. Unscrew the two Base Plate screws and remove the Control Assembly. See Fig. 44. BASE PLATE SCREWS BASE PLATE WITH CONTROL ASSEMBLY...
  • Page 19: Step 11: Wiring

    HE120 BY-PASS DRUM HUMIDIFIER STEP 11: WIRING 4. At the transformer, connect both white conductors to the two transformer terminals. See Fig. 50. WARNING Hazardous Voltage. Can cause personal injury of equipment damage. Disconnect power supply before installing or servicing equipment.
  • Page 20: Step 12: Testing And Checkout

    The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.
  • Page 21 Humidificateur à dérivation à tambour HE120 NOTICE D'INSTALLATION Table des matières Déballage de l'appareil ................................... Installation ........................................Étape 1 - Choix du meilleur endroit pour l'humidificateur ...................... Étape 2 - Installation de l'humidificateur ............................Étape 3 - Installation du collet de dérivation ..........................
  • Page 22: Déballage De L'appareil

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 DÉBALLAGE DE L'APPAREIL Cette boîte contient toutes les pièces nécessaires pour installer l'humidificateur HE120 dans la plupart des cas. Avant de continuer, il est préférable de se familiariser avec toutes ces pièces. • Boîtier de l'humidificateur •...
  • Page 23 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 • Extrémité ouverte du • Extrémité fermée du tambour tambour U Fil de thermostat à deux conducteurs de cal- ibre 18, 6 m (20 pi) V Tuyau à eau en plastique de 0,64 cm (1/4 •...
  • Page 24: Installation

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 • Choisir un endroit où la gaine de dérivation de 91 cm INSTALLATION (3 pi) peut être raccordée au collet de dérivation de l'humidificateur. Avant d'installer ce produit… 1. Lire attentivement les présentes instructions. Le fait...
  • Page 25: Étape 2 - Installation De L'humidificateur

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 4. Déterminer l'endroit de l'alimentation en eau • L'humidificateur fonctionne avec de l'eau dure ou de l'eau douce. • L'eau peut être chaude ou froide. • S'assurer que le tuyau d'alimentation en plastique de 6 m (20 pi) est assez long pour raccorder l'alimentation d'eau (robinet-vanne à...
  • Page 26 22 cm en dessous La gaine tambour, le bac d'eau et la plaque du moteur. doit avoir une largeur minimale de 28 cm 7. Placer le boîtier de l'humidificateur HE120 de (11 po). niveau, sur l'ouverture, et marquer l'emplacement des cinq trous de montage.
  • Page 27: Étape 3 - Installation Du Collet De Dérivation

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 3 - INSTALLATION DU 2. Tracer une ligne à l'intérieur du collet et marquer la position des trous de montage. COLLET DE DÉRIVATION 3. Retirer le collet et découper soigneusement l'ouverture circulaire à l'aide des cisailles à tôle. Voir la figure 9.
  • Page 28 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 4. Percer les trous de montage à l'aide d'un foret de 3 5. Si le registre optionnel doit être installé, poser une mm (1/4 po). Si le registre optionnel est installé, ne vis à tôle n 8 de 1,9 cm (3/4 po) dans le registre et le pas percer le trou à...
  • Page 29: Étape 4 - Installation De La Gaine De Dérivation

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 4 - INSTALLATION DE 3. Fixer la gaine de dérivation à l'humidificateur avec au moins trois vis à tôle n 8 de 1,9 cm (3/4 po). Voir LA GAINE DE DÉRIVATION la figure 14. Percer des avant-trous à l'aide d'un foret de 3 mm (1/8 po).
  • Page 30: Étape 5 - Assemblage Du Tambour De L'humidificateur

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 5 - ASSEMBLAGE DU 3. Glisser le tampon évaporateur par-dessus les tiges de l'extrémité fermée. Voir la figure 18. TAMBOUR DE L'HUMIDIFICATEUR 1. Glisser l'extrémité fermée du tambour sur l'arbre, les tiges rondes à l'opposé des pattes en métal. Voir la figure 16.
  • Page 31: Étape 6 - Assemblage De L'humidificateur

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 6 - ASSEMBLAGE DE 4. Enclencher la plaque du moteur en place. 5. Passer les fils du moteur dans le trou au bas du L'HUMIDIFICATEUR couvercle du moteur et les fixer sur la surface extérieure de l'humidificateur.
  • Page 32 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 RACCORD D’ÉVACUATION FLOTTEUR MOTEUR ROBINET À FLOTTEUR MF13626 Fig. 24. Bon emplacement du robinet à flotteur. MF13628 Fig. 27. Installation du raccord d'évacuation. PAROI DU BOÎTIER DE L’HUMIDIFICATEUR 9. Installer le bac d'eau dans le boîtier de l'humidificateur de façon que le tube de trop-plein...
  • Page 33: Étape 7 - Installation Du Drain

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 7 - INSTALLATION DU ÉTAPE 8 - INSTALLATION DU DRAIN ROBINET-VANNE À ÉTRIER MISE EN GARDE MISE EN GARDE Risques de dégâts d'eau Dangers reliés aux produits chimiques Peut causer des dommages matériels.
  • Page 34 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 3. Assembler le robinet-vanne à étrier sur le tuyau en 4. Serrer les vis uniformément - les supports doivent cuivre à l'aide de vis à tôle n 10 de 4,5 cm (1 3/4 po).
  • Page 35: Étape 9 - Installation Du Tuyau D'eau

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 9 - INSTALLATION DU 2. Glisser le manchon de compression en plastique sur le tuyau. TUYAU D'EAU 3. Poser la garniture en laiton dans l'extrémité du tuyau en plastique. REMARQUE : Pour prévenir les fuites, utiliser le manchon...
  • Page 36: Étape 10 - Installation De L'humidistat

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 10 - INSTALLATION DE 3. Voir la figure 37 et suivre les étapes ci-dessous pour découper l'orifice de montage de l'humidistat. L'HUMIDISTAT a. Percer un trou de 13 mm (1/2 po) au centre du gabarit.
  • Page 37: Montage Au Mur

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 5. Dévisser et retirer le couvercle arrière de l'humidistat. Voir la figure 39. GAINE JOINT RÉGULATEUR BOUTON DE RÉGLAGE MF12841A Fig. 39. Retrait du couvercle arrière de l'humidistat. Fig. 42. Fixation de l'humidistat sur la gaine.
  • Page 38 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 5. Dévisser le couvercle arrière de l'humidistat et le 9. Placer la plaque de montage horizontalement par- retirer. Voir la figure 39. dessus le fil, puis tirer le fil par le trou. 6. Dévisser les deux vis de la plaque de montage et 10.
  • Page 39: Plaque De Montage

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 PLAQUE DE MONTAGE VIS DE 0,9 cm (3/8 po) COUVERCLE CADRAN DE POINT DE CONSIGNE MF13614A Fig. 48. Assemblage du couvercle de l'humidistat. 69-1860EF—02...
  • Page 40: Étape 11 - Raccordement

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 11 - RACCORDEMENT 4. Raccorder les deux conducteurs blancs aux bornes du transformateur. Voir la figure 50. AVERTISSEMENT Risques liés au courant électrique Peut causer des blessures ou endommager l'équipement. Couper l'alimentation électrique avant d'installer l'appareil ou de faire l'entretien.
  • Page 41: Étape 12 - Essai Et Vérification

    HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 ÉTAPE 12 - ESSAI ET 9. S'assurer qu'il n'y a pas de fuite d'eau au raccord du robinet-vanne à étrier ou au raccord du robinet à VÉRIFICATION flotteur. Resserrer si nécessaire. 10. Régler l'humidistat au point de consigne pour assurer le confort et le laisser fonctionner 1.
  • Page 42 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 69-1860EF—02...
  • Page 43 HUMIDIFICATEUR À DÉRIVATION À TAMBOUR HE120 69-1860EF—02...
  • Page 44 The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.