vvH : switch
00H=on
10H=off
F7H : EOX
Mixture Cancel
Data format: F0H 31H 2FH 6BH vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
6BH : mixture cancel
vvH : switch
00H=on
10H=off
F7H : EOX
Cancel
Data format: F0H 31H 2FH 6CH 00H F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
6CH : cancel
00H : execute cancel
F7H : EOX
Couplers (3 and 4 manuals)
Data format: F0H 31H 2FH 70H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
70H : coupler
vvH : type and switch
00H=III/P - REC/PED on
10H=III/P - REC/PED off
01H=II/P - GO/PED on
11H=II/P - GO/PED off
02H=I/P - POS/PED on
12H=I/P - POS/PED off
03H=III/II - REC/GO on
13H=III/II - REC/GO off
04H=I/II - POS/GO on
14H=I/II - POS/GO off
05H=III/I - REC/POS on
15H=III/I - REC/POS off
F7H : EOX
Data format: F0H 31H 2FH 70H 7FH vvH nnH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
70H : coupler
7FH: other coupler
vvH nnH:
type and switch
04H 21H:IV/P - SO/PED on
04H 20H:IV/P - SO/PED off
14H 21H:IV/II - SO/GO on
14H 20H:IV/II - SO/GO off
24H 21H:IV/III - SO/REC on
24H 20H:IV/III - SO/REC off
34H 21H:IV/I - SO/POS on
34H 20H:IV/I - SO/POS off
-
This message is received only.
Couplers (2 manuals)
Data format: F0H 31H 2FH 70H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
70H : coupler
vvH : type and switch
00H=II/P - REC/PED on
10H=II/P - REC/PED off
01H=I/P - POS/PED on
11H=I/P - POS/PED off
03H=II/I - REC/GO on
13H=II/I - REC/GO off
F7H : EOX
-
This message is received only.
Sub- and super-octave
Data format: F0H 31H 2FH 70H vvH ssH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
70H : coupler
vvH ssH:type and switch
22H 11H=REC 16' on
22H 10H=REC 16' off
22H 31H=REC 4' on
22H 30H=REC 4' off
12H 11H=Accoupl. REC/GO 16' on
12H 10H=Accoupl. REC/GO 16' off
32H 11H=Accoupl. REC/POS 16' on
32H 10H=Accoupl. REC/POS 16' off
F7H : EOX
-
This message is received only.
Orchestra volume
Parameter: Orch.
Video page: Volumes
Data format: F0H 31H 2FH 72H vvH F7H
F0H : Exclusive status
31H : Viscount ID
2FH : system control
72H : orchestra volume
vvH : orchestra volume value (00H – 7FH)
F7H : EOX
SYSTEM REAL TIME MESSAGES
FEH: Active Sensing
FEH is transmitted every 300 msec. whenever is no
other MIDI data being transmitted.
113