Autres Spécifications D'installation - RJG 211M18 Manuel Du Produit

Capteur de rondelle de charge piézoélectrique
Table des Matières

Publicité

AUTRES SPÉCIFICATIONS D'INSTALLATION
Drawing Title: 211M18-04
NOTES:
1.
ENCLOSED EJECTOR BOX SUGGESTED.
2.
DO NOT SCALE PRINT
3.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
4.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
5.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
10
RJG, Inc.
Piezoelectric Load Washer Sensor 211M18 Optional Installation
Customer-supplied spacer required if head of sleeve contacts
less than 80% of sensor loading surface.
C
Spacer
Contact Surface
.01
.67 +
.00
-
+ 0.3
16.9
0
DETAIL C
SCALE 3 : 1
.01
.01 +
-
.00
+ 0.25
0.25
0
not to exceed 20% of
part wall thickness
0.03-0.06
[0.76–1.52]
Sleeve Head
Counterbore
.003
.410 +
-
.000
+ 0.08
10.41
0
DIA of Sleeve Head + 3.0 [.12]
if Sleeve Head > Sensor DIA
.263±.003
6.67±0.08
Description: 211M18 Sensor
Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 01.27.2022
Capteur de Rondelle de Charge Piézoélectrique 211M18 | Manuel du Produit

Publicité

Table des Matières
loading

Table des Matières