23. OPERATION (
CONT
E
L
P
RASE
INK
ROCESS
A. A
"
"
CTIVATE THE
LINK
MODE OF THE HOOD
Push the LinkLogic link mode push-button (item 4 on control illustration) for 2 seconds; the LinkLogic icon of the interface (item 11 on
control illustration) should be visible and backlighting is full intensity at that point.
B. E
L
L
RASE ALL LINKED
INK
Push the LinkLogic erase link push-button (item 3 on control illustration) for 2 seconds to start the "Erase Link" process, flashing "E"
should be visible (item 8 on control illustration) on the hood interface until links are erased.
C. E
"
"
XIT
LINK
MODE OF THE HOOD
Press and hold LinkLogic link mode push-button (item 4 on control illustration) for 2 seconds to exit "link" mode. Link mode remains
activated for 4 minutes if no other operation is done.
NOTE: If during normal operation of the range hood, the LinkLogic Icon (item 11 on control illustration) starts blinking, an error occurred
while communicating with a linked LinkLogic device. To reset this error flag, customer needs to enter and exit the Linking mode
as explained previously. This will erase the error flag until it happens again. If the problem happens again, it is recommended to
erase all links and start back the whole linking process.
24. LINKLOGIC SYSTEM CONTROL BOARD JUMPERS
The LinkLogic system is designed to work with devices like the Broan Smart Sense Fan system that requires CFM output or this range
hood. If you are using this hood with a LinkLogic device that requires CFM information, please follow the simple instruction/matrix below to
configure the LinkLogic control board in the hood to provide the correct CFM information. To access the LinkLogic control board, remove
baffle filters, grease drip rail and hood pan (see steps 5 and 6). Remove both screws retaining the control panel to the hood. Rotate
carefully the control panel in order to see the LinkLogic board jumpers. Remove jumpers from current location on pins and reconfigure
based on blower performance.
3
2
1
HE0089
L
L
INK
OGIC BOARD JUMPERS
If you are unsure if the LinkLogic accessory or device requires CFM data, please refer to the unit's instructions.
'
)
D
OGIC DEVICES
Pin 1
Pin 2
Pin 3
0
0
0
0
0
1
0
1
0
0
1
1
0 = No jumper on pin.
1 = Jumper on pin.
Maximum CFM value
0 CFM
300 CFM
500 CFM
600 CFM
0 = No jumper on pin.
1 = Jumper on pin.
16
Pin 1
Pin 2
Pin 3
Maximum CFM value
1
0
0
1
0
1
1
1
0
1
1
1
900 CFM
1000 CFM
1200 CFM
1500 CFM