16. INSTALL THE BLOWER (
Refer to instructions included with blower.
Once the blower is installed, plug the blower cord (A) into the female receptacle
and the power supply cord (B) onto the male connector inside the hood.
Do not plug the two cords into each other.
17. INSTALL THE CALIBRATION BUTTON BRACKET IN THE HOOD
(iQ6 AND iQ12 INTERIOR BLOWERS ONLY)
Both iQ6 and iQ12 blowers are equipped with a calibration button
already mounted to its own bracket. Install this bracket in the hood, using
2 screws provided with iQ6 or iQ12 interior blower.
18. REINSTALL THE PAN
Remove protective plastic film covering pan sides and tape over halogen lamps.
Using a Phillips no. 2 or Robertson no. 2 screwdriver and the retaining screws, reinstall the pan
(previously removed in step 6) inside the hood (shaded part on illustration at right).
INTERIOR OR EXTERIOR BLOWER
WARNING
!
)
HE0078
HD0540
CAUTION
11
A
B
R
ETAINING SCREWS LOCATION
HD0224