Generator Maintenance; Lcd Contrast - Cebora 3.300.154/A Manuel D'instructions

Poste a souder a fil
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
• Post Gas
The adjustment can vary from 0 to 25 seconds.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob B for less
than 2 seconds.

• LCD Contrast

The adjustment may range from 0 to 100%.
This function can be used to increase or decrease the
brightness of display screen A.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob B for less
than 2 seconds.
• Factory OFF
The purpose is to return the welding machine to the
original default settings.
To access the function, simply highlight it using the
knob B. By pressing this for less than 2 seconds, the
display screen A shows the words OFF and ALL. By
highlighting the word ALL and briefly pressing the knob
B reset is made and the display screen A shows Factory
Done!! This indicates the reset has been successful. To
return to the previous display page, simply press the
knob B for more than 2 seconds.
NOTE. For all the functions adjusted by means of the
adjustment bar, the initial default value can be reset.
This operation be performed by pressing the knob B
for more than 2 seconds only once the adjustment bar
appears on the display screen A (Arc Lenght - Spot Time
- Pause Time - Inductance, Burnback – Soft Start - Pre
Gas - Post Gas - LCD Contrast).
16
PostGas
25.0s
3.0s
0.0s
LCD Contrast
MAX
50%
MIN
Factory
OFF
ALL
8 MAINTENANCE
All
maintenance
jobs
professional personnel according to the CEI 26-29
(IEC 60974-4) standard.

8.1 GENERATOR MAINTENANCE

In case of maintenance inside the appliance, make sure
the switch F is in "O" position and that the power supply
cable is disconnected from the mains.
Periodically, also clean the inside of the appliance and
remove any metal dust using compressed air.
8.2
HOW TO PROCEED AFTER MAKING REPAIRS.
After making repairs, always ensure the wires are fully
insulated between the primary side and the secondary
side of the machine. Avoid the wires coming into contact
with moving parts or parts that heat up during operation.
Fit all the clamps back as on the original machine so as to
avoid any contact between the primary and secondary in
case of accidental lead breakage or disconnection.
Also fit the screws back on with the toothed washers as
on the original machine.
must
be
performed
by

Publicité

Table des Matières
loading

Table des Matières