UVC lamp replacement
Attention! Breakable glass.
Possible consequences: Injury to your hands caused by cuts.
Protective measures: Handle the quartz glass and UVC lamp with care.
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
• Never operate the UVC lamp outside its casing.
• Never operate the UVC lamp in a casing that is defective.
• Open the UVC water housing (see "Opening and cleaning the UVC water housing").
• Remove the self-tapping screw (32).
• Unscrew the clamping screw (34) from the unit head (31) by turning counter-clockwise.
• Pull off the quartz glass (33) and the O-ring (35) while slightly turning the unit head (31).
• Pull out the UVC lamp (36) and replace.
Important: Only use lamps the identification and capacity data of which correspond to the information on the type
plate.
• Check the quartz glass (33) and the O ring (35) for damage.
• Insert the quartz glass (33) including the O ring (35) against the stop in the unit head (31).
• Tighten the clamping screw (34) clockwise up to the stop.
• Turn in and tighten the self-tapping screw (32).
• Close the UVC water housing (see "Closing the UVC water housing").
Storage/overwintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!

Wearing parts

The UVC lamp, the different filters and the rotor are wear parts and are excluded from the warranty.

Spare parts

The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
Note
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided
for this purpose.
Only dispose of the UVC lamp by using the return system provided for this purpose.