Wear Parts; Spare Parts - Oase Aquarius Fountain Set Eco 5500 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Cleaning the pump
How to proceed:
 F
1. Unscrew the transition piece.
2. Remove the two screws and open the filter housing.
3. Take out the pump.
4. Remove the screws of the pump casing and pull off the pump casing.
5. Pull out the impeller unit (magnetic resistance).
6. Clean all parts.
Reassembling the unit
How to proceed:
 G
1. Place the pump into the strainer casing.
2. Route the connection cable through the cable opening in the filter housing.
3. Replace the filter cover, turn in the two screws and hand tighten.
4. Screw on the transition piece together with the flat seal.
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Store the pump submerged and in a frost-free environment.
• Protect open plug connections from moisture and dirt.

Wear parts

• Impeller unit

Spare parts

The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
www.oase-livingwater.com/spareparts
- EN -
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquarius fountain set eco 7500Aquarius fountain set eco 9500

Table des Matières