Display
Basic Function
En
ENCODER USE:
You can enable/disable the use of encoders
encoders):
Y
= encoders on both motors
no
= encoders disabled
FA
LIMIT SWITCH WHEN OPENING (displayed only if function
CF
PC
=
Lets you set or disable use of the opening limit switch on swing-leaves .
In case of mixed configuration (
on the swing-leaves. The limit switch on the SLIDING leaf is required
and determines when the leaf stops.
no
= opening limit switches disabled
01
= the limit switch determines the stopping of motion
02
= the limit switch determines the start of deceleration
After having changed the value of this function, SETUP is required:
the card will signal error
performed again or until the previous value is restored
FC
LIMIT SWITCH WHEN CLOSING (displayed only if function
CF
PC
=
Lets you set or disable use of the closing limit switch on swing-leaves.
In case of mixed configuration (
on the swing-leaf. The limit switch on the SLIDING leaf is required
and determines when the leaf stops.
no
= closing limit switches disabled
0 1
= the limit switch determines the stopping of motion
02
= the limit switch determines the start of deceleration
After having changed the value of this function, SETUP is required:
the card will signal error
performed again or until the previous value is restored.
Br
SLIDING LEAF BRAKING (displayed only if function
PC
=
):
Lets you set the braking time of sliding leaves.
00
= braking disabled
10
= maximum braking time
SAFEzone RETROFIT KIT
):
):
(both BUS and GATECODER
CF
PC
=
) this function works only
14
(configuration error) until the SETUP is
CF
PC
=
) this function works only
14
(configuration error) until the SETUP is
5
Default
CF
1
=
or
CF
1
=
or
CF
2
CF
=
or
532037 - Rev. B
no
no
no
05